The incinerator mounted in ISO Container before leave factory, free-installation, no incineration house build construction,movable by truck.
About Hiclover Medical Enviromental
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction […]
Medium/Large Scale Waste Incinerators
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel…
Required Specifications for Mobile Incinerator
Operational Capabilities PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS ABILITY TO BURN WASTE LUBRICANTS (POL) HANDLE ORGANIC SOLIDS (TO INCLUDE RMW) DEPLOYABLE MOBILE 24 HRS OF CONTINUOUS USE AUTOMATIC LOADING […]
hospital incinerator manufacturers
SECTION V TECHNICAL SPECIFICATIONS OF THE INCINERATOR General Description The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to: Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers […]
hospital incinerator manufacturer
Up to 600kgs per ten-hour day of Type IV pathological waste or red bag waste rated at 2200 BTU’s per kg, based on batch loading twice daily. Incinerator, 20 kg/hr Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day) (4-6 hours operations) (Power Supply 380V, 50Hz, 3Ph) Capacity: 30 […]
laboratory incinerator china manufacturer
Incinerator dual chamber with capacity 1.5 m3/batch or 6 m3/ day, digital thermocontrol range 0‐1200 C, thermocouple, air supply capacity 10m3/ minute, power consumption 1.2kWH/ hour, power 3 phase with netral, cooling water sprinkler capacity 5L/ minute, completed with refractory (insulation, castable, ceramic blanket) and PLC SUPPLY, INSTALLATION AND COMMISSIONING […]
incinerator type of pyrolytic medical waste incinerator capacity
Including:Incinerator: Structure to be specified The mark to be specified Water temperature: 800 to 1000 ° C; Refractory Temperature of more than 1100 ° C + obtained; Capacity: 20-50 kg / hour Fireplace: 4 to 6 meters high; Dimension 70 cmx70 crn Height: 1.10 meters Fuel: coal; Aspiration: natural – […]
diesel oil fired medical waste incenerator
High Temperature Waste Incinerator Model D. MB 750XL Burn Rate-150Kg/hour minimum Weight(Kg)-4000kg Secondary Chamber (double chamber with post-burning) Gas Retention Time 2 second Fuel Diesel Power Supply for control box 220V-240, single phase 50-60Hz Minimum operating temperature 1200 oC One year spare parts package for complete maintainability 10m hose pipe. […]
manufacturer of ha zardous waste incinerator in china
Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system Imputing door Mouth Width (mm): 760*760 (approx.) Chimney External Diameter (mm): 300 ± 10 Combustion Improver Device: 0.11kw, Fuel consumption: 7kg/ hour (max) Re-Burning Device: Oil consumption: 5kg/h, 0.37kw, Oil consumption: 10-20kg/h Voltage: 380v/220v AC, Warranty: 1 Year, 50 […]
portable medical waste incinerator manufacture companies in china
Capacity: 20KG/Hr, Temp Range: 600 Deg. C – 1100 Deg. C Fuel Supply: Natural Gas/Diesel Dual Combustion Chamber Complete Scrubbing System (Dual Resultant Gas Washer), Dual Blower, Chimney Height: 8m Electric Supply: 220/240Volt, Single Phase 1. Type of waste: Trash 2. Any other type: 3. Quantity of waste generated per […]
infectious waste pyrolysis machine chinalarge animal incinerators
Major components are – Ethanol, Paraffin, Silicon, Aluminium chloro hydrate, Bentone ,LPG quote for incinerators for industrial chemical wastes treatment, 1 burning rate must be Average 30kgs\h 2 inside of chamber material must be refractory concrete cement 3 it works in three system diesel oil\ Natural gas or LPG 4 […]
low-cost medical waste incinerator
Stack: Type: Wire Supported MOC: Mild Steel of ISstd Height :3 Meters or more • PROCESS AT LEAST 1 METRIC TON OF WASTE PER DAY • OPERABLE BY 1 PERSON, WITH NO TRAINING REQUIRED • REGULAR MAINTENANCE CAN BE COMPLETED BY 1 PERSON WITH LIMITED TRAINING • REGULAR MAINTENANCE SHOULD […]
china incinerator manufacturer and exporter
Primary Combustion Chamber Waste Charging Door: Provided with refractory lining with sealing gaskets Ash Removed Door: Provided with refractory lining with sealing gaskets Outer Body MOC: Mild Steel, 5mm Primary Chamber: Stainless Steel Operating Temperature :800. ± 50◦C Insulation: Insulation Brick Heating Elements Type: Kanthal Al Grade Power Consumption: 75 […]
incinerator manufacturer in china
1. Is the residence time more than 2 seconds? 2. Is the primary and secondary air preheated? 3. Could it be provided as a continuous system? 4. Is there a monitoring system for operational parameter? (temperature) 5. Is there a data logging system? 6. Does it provide for control interventions […]
waste incinerator manufacturer in china
Burning rate: 250 Kg/hr. It should be able to Operate not Less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification: Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the […]
medical waste incinerator manufacturer
GOODS: ONE INCINERATORS IN ACCORDANCE WITH THE SUPPLIER’ REQUIREMENT S OWN PROPOSED SPECIFICA TION/ CONFIRM […]
incinerator manufacturers
GOODS: ONE INCINERATORS IN ACCORDANCE WITH THE SUPPLIER’ REQUIREMENT S OWN PROPOSED SPECIFICA TION/ […]
TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals in Kenya
TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals INTRODUCTION All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination […]
00 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS
1) Policy – Waste disposal management shall be taken special note to prevent hospital infection. – Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site. 2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows; Infections Waste Specially-controlled waste […]
incinerator manufacturer
“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must avoid the release of black smoke and fine dust, during the loadings. It shall be able to reduce the volume of wastes by 98%. It shall be able to hold emission in the second burn with gas residence […]
pet incinerator
The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance. Capacity of destruction in weight shall be 60 Kg/h. It should be able […]
mobile incinerator
Petrol: diesel Consumption: 8-10liter/hour Capacity: to cremate (carrion and spoils) 350-400kg/hour Temperature: 900-1350?C Operation temperature: -30~40?C Incinerator weight: 1800-2000 kg Volume: 0.70-0.80m/cube Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) An incinerator represents a complete solution to the problem of disposal of all hospital waste types. The […]
hospital incinerator
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. * A secondary injection of air to ensure perfect oxygen content. 19. A control box ensuring the complete cycle of combustion. 20. Fan: […]
medical incinerators
* medical incinerators, The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal. * Composition of the refractory; ? Refractory concrete : ? . Thickness : ≥100 […]
pet incinerator for sale
1. Capacity of destruction in weight: 60 Kg/h. 2. It should be able to operate not less than 10 hours/day 3. This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4. Design Specification : Types A, B, C, D, and E […]
hospital incinerator design
INCINERATEUR DE DECHETS HOSPITALIER hospital incinerator design SPECIFICATIONS TECHNIQUES. Capacité destructive de 55 Kg/h jour de déchets hospitaliers avec un p?.c. i jusqu’à 3.200 Kcal/Kg 1)Type de déchet hospitalier 2)Pouvoir calorifique inférieur 3.200 kcal/kg 3)Humidité 20% 4)Teneur en cendres et/ou inertes 8% 5)Capacité destructive nominale 55 kg/h 6)Volume chambre de […]
medical incinerator primary combustion price
Our normal activities generates 2-5 tons of assorted waste materials per day which range from condemned carcasses, and medical incinerator primary combustion price other wastes all which need to be incinerated at above 800Centigrade measured flue exhaust gas.To be used by small hospitals and clinics to safely dispose of infectious […]
waste incinerator manufacturers china
Capacity Not less than 500Kg/hr. Operation 24hr-7days/week continuous operation. Combustion chamber 2 combustion chamber. Temp. First combustion chamber 800-1000 C. Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400 C. Combustion Efficiency 99.99% Retention time Of the flow gases not less than 2 Sec in the […]
small capacity incinerators
1 Basic Plant Design An approved plant must have four distinct sections that demonstrate three principles of Turbulence, Residence Time and Temperature are inbuilt in the plant design .The regulated sections may include but not limited to: Overall plant layout. Feed chamber/ charging Primary Combustion Chamber. Secondary Combustion Chamber. Particulate […]
china medical incinerator
the following containerized incinerators. (Kitchen and accommodation and grey water and black water plant removing waste) we need incinerator is each function separate are all in one incinerator we need informed. Plant we installing for our accommodation barge used in an offshore marine construction project. 200 People would be accommodated […]
waste incinerator manufacturer china
waste incinerator manufacturer china, Waste chamber Chamber capacity 300 kg Chamber volume .54m3 Chamber size (outside) Width: 91cm, Height: 86cm Length: 152cm Door opening 66 x 76 cm Height to door 84 cm Height to top of stack 5.4 m Suggested slab size (L x W x Thickness) 1.8 m […]
cheap incinerators
RECYCLABLE WASTE PLASTIC (NON-PVC) 218,693 CARDBOARD 85,046 PAPER 4,956 PVC 15,115 HAZARDOUS WASTE MEDICAL WASTE 1,084 SOLID WASTE CONTAMINATED WITH HYDROCARBONS 300,680 USED ENGINE OIL FILTERS 85,423 HYDROCARBON-CONTAMINATED SOILS 88,680 ORDINARY WASTE FIBERS 14,078 USED AIR FILTERS (AUTOMOTIVE AND SIMILAR) […]
animal waste incinerator manufacturer
Technical specification for burning machine,animal waste incinerator manufacturer 1.Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by custom authority to burn different kinds of drugs. All need equipment must be provided. 2.Warrantee: booth systems must be […]
medical waste incinerator china
medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: – · Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste · Waste density: 125 to 350Kg/M3 · Waste CV: 4000 KCAL/kg · Moisture content: 10-25% · Estimated […]
chinese incinerator manufacturers
In a simple design with a metal steel drum electric. including: A cage for receipt of biomedical waste; A combustion chamber with fireplace with a filter to retain ashes; A cover; An air supply; A turbine allowing the supply of the air. Combustion temperature: 1800 ° C. Compliance with European […]
hospital incinerator manufacturers
The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and also produced high pressure steam from incinerator plant heat generated. At first output waste from petrochemical collects and transfers to transit and sorting center in […]
medical waste incinerators manufacturers
chemical agents to be utilized: 10% heptyl (unsymmetrical dimethylhydrazine) water solution, heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration, 10% azotic (nitric) acid water solution, azotic (nitric) acid vapour with concentration up to 1.1 kg/m3; 2. neutralization method: thermal decomposition; 3. neutralization temperature: +800?C to +1200?C; 4. performance: […]
medical waste incinerator
medical waste incinerator: medical waste and general waste Capacity to burn waste: 400 — 500 kg/hr Fuel: Diesel Fuel Consumption: 10 litres/hr maximum Incineration temperature: 950 – 1300 °c Casing: thick (min 5 mm) Stainless steel casing and fully insulated to withstand sea humidity Voltage: 220/240 V or 380/415V Frequency: […]
medical waste diesel incinerator
medical waste diesel incinerator Burning Rate:47.5–50kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density Insulation:20mm High Refractory Casting:Minimum 65mm Heavy duty refracting lining to withstand:1500 oC Average burn out time :maximum:3 hrs Fuel type:Diesel Fuel Consumption in L/hr:7.5 to 9 Residence time in secondary […]
waste incinerator manufacturers from china
Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz high-capacity, powerful, European Standard incinerator,ideal for high […]
incinerator for medical waste
MINIMUM REQUIREMENTS FOR ENGINE OF INCINERATION CAPACITY OF INCINERATION 30KG / H 1. GENERAL SPECIFICATIONS: The incinerator for medical waste must be designated for the destruction of all types of waste produced by the Center for Health (waste type hospital, clinic, medical laboratory for destructive capacity of 30kg / h) […]
small scale medical waste incinerator
Toxic and dangerous wastes, Medical pharmaceutical and hospitable liquids Wastes Domestic garbage Electric and electronic wastes Industrial wastes In General, all type of wastes and garbages Capacity 50-60Kg/h Combustion supporting materials Coal oil, diesel oil Temperature inside 800-10000C 1000-12000C Burning efficiency >98% Power consumption 1.3KW Noise <78dB Index of let […]
medical waste incinerator for sale
Waste type: health care waste Waste density: 125 to 350Kg/M3 Waste calorific value: 4000KCAL/kg Moisture content: 10 – 25% Estimated ash residue: 5 – 10% Nominal capacity: 50kg/hr batch load Secondary chamber: 2 seconds@850?C Environmental: NEMA ACT (EMCA) 1999, Waste Management regulations, 2006 Primary Combustion chamber: The primary combustion chamber […]
incinerator manufacturers
1. SCOPE OF WORK The work specified in the contract will include. 1. Supply, install and commission an incinerator as provided in the technical specifications 2. Provision for adherence to OSHA and other statutory requirement relating to Health and Safety of workers during execution of the works covered in this […]
medical incinerator manufacturer
1.The double chamber incinerator shall preferably be designed. Air supply in the primary and secondary chamber shall be regulated between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement device shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a […]
laboratory incinerator
the entire carcass of animals ( cattle , horses , Sheep, pigs , etc.) , as well as biologically hazardous waste Products in the fuel stove . ? Opening Doors – the closure and fixation automated system , Which are managed remotely by the operator . ? designed to work […]
medical incinerators
● Able to burn 25-30kg per hour ● Consist of two chambers to ensure significant reduction in emission ● Be capable of temperature in range of 800c to 1000c ● Low maintenance design ● Must be Diesel fuelled ● Need more than 15amp 220- 250V power ● kW Consumption power […]
small scale incinerator
Incinerators Biological waste disposal system (incinerator) Incinerator must meet the following specifications: – Combustion capacity (kW) = 581 +/-10% – Combustion capacity (kcal/h) = 500,000 +/-10% – Max. l/h (at approx.. 50% water content) = 100 +/-10% Further specifications will be provided with the inquiry. The incinerator shall be fully […]
animal incinerators for sale
SMART ASH INCINERATORS FOR THE DISPOSAL OF HAZARDOUS WASTE ? Quantity: 20 units ? The Incinerator works with a 55 gallon open ended steel drum ? The unit operates without fuel and used only 120v or 220v electricity for the blowers ? Unit is capable of burning oil contaminated waste […]