Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods.Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. ※Main Feature:–Three Combustion Chambers or A/B Primary Combustion Chamber— Double or Three Italy Burner–Burning Rate: 80-800kgs per hour–Combustion Chamber: 1.0M3-10.0M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner — Upgrade/Downgrade Burning Rate WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion […]
Pet Animal Crematory Incineration
Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods.Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. ※Main Feature:–Three Combustion Chambers or A/B Primary Combustion Chamber— Double or Three Italy Burner–Burning Rate: 80-800kgs per hour–Combustion Chamber: 1.0M3-10.0M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner — Upgrade/Downgrade Burning Rate WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion […]
HICLOVER Made Waste Incinerators
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction […]
HICLOVER Made Waste Incinerators
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction […]
3 Chambers Incinerator
Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control
3 Chambers Incinerator
Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control
Incinerator factory
Key Features: — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.— System solutions for medical waste environmental.— High burn rate, from 5kgs to 1000kgs per hour.— New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC […]
HICLOVER Waste Incinerator Front view
— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators. — System solutions for medical waste environmental. — High burn rate, from 5kgs to 1000kgs per hour.— New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm […]
Containerized Mobile Incinerators
○ Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to […]
small waste incinerator for ZAMBIA model YD30C
YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, like hospital, environmental department, animal cremation agencies, etc. CLOVER Incinerator supply updated models with dual combustion chamber, mix combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C. Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Common Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel) WWW.HICLOVER.COM|Waste Incinerators |Auto Roll […]
SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR – TECHNICAL SPECIFICATIONS
SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR – TECHNICAL SPECIFICATIONSThe Waste Incinerator is designed to burn Type IV of pathological waste and infectious, contaminated “red bag,” surgical dressings, plastic test devices and other wastes. General SpecificationsBurner: 2 burners (primary burner and second burner) Fuel: Oil Capacity (Cubic Mtr): 0.65 Ave Capacity: 60 kg per hour Fuel Consumption (ltrs / hr):13 External DimensionsLength (mm): 2300 Width (mm): 1220 Height Incl. Flue (mm) 7000 Door Opening (mm) 610 x 710 610 x 710OperationMin. Operating Temperature: 950 Max. Operating Temperature: 1320 Residency Time in Second Chamber: 5 sec Temperature Monitoring: YES Other clarificationEasy and safe operationLarge counter-balanced fill door with electrical lockout.Automatic control system provides preset burn times and shut off. Reload light indicates to operator when it is time to recharge. Be required for burnout of final charge. Low energy consumption levels Programmable digital temperature controls maintain temperature, assuring complete combustion while conserving fuel. Pressure blower with modulating air control creates turbulence and distributes combustion air to secondary chamber. Secondary burner with temperature activated modulating control provides fast preheat and sustains high temperature performance at low energy consumption levels. Charging rate Up to 600kgs per ten-hour day of Type IV pathological waste or red bag waste rated at 2200 BTU’s per kg, based on batch loading twice daily.Thermocouples (2 pcs/ each thermocouple assembled on the unit )Thermocouples with pocket (1 pcs/each burner )Nozzles (2 pcs/burner)Nozzle line (1 pc/burner)Glass fibre (2 roll/size)Ignition electrode ( 2 pcs/burner)High tension cable ( 2 pcs/burner)Flame photometer (1 pcs/burner)Burner primary chamber (1 set)Burner secondary chamber (1set)Control panel parts (1 set)Fuse (1 pk from each rating )Solenoid valve (1 pcs/assembled on the unit)Burner oil filter (10 pcs/burner)Fuel pump (1 pcs/burner)Shaft seal kit (1 set /shaft)Seal plate gasket ( 1 set / plate )Mechanical seal (1 set)Flue gas restricting ring bricks (1set)Refractory cement (1 pk ) Shaft bearing (1 set)V belts (1 set)
The Jamaican National Trade Effluent Standards (1995)
The Jamaican National Trade Effluent Standards (1995) PARAMETER STANDARD LIMIT Ammonia /Ammonium 1.0 mg/l Barium 5.0 mg/l Beryllium 0.5 mg/l Boron 5.0 mg/l Calcium No Standard Chloride 300 mg/l Colour 100 TCU Detergent 15 mg/l or <0.015 kg/ 1000 kg product Fluoride 3.0 mg/l Iron 3.0 mg/l Magnesium No […]
Waste Incinerator Chambers
A chamber of post combustion of gases * A burner of combustion of gases, * A device of injection of air allowing a total re-combustion of gases, * A device of air inlet of cooling of waste gases, * A sheath of evacuation of the gases burnt. * Carcass in […]
Waste Incinerators
10.A ready built fabricated room shall be supplied for housing the incinerator. The room will be designed in such a way that free space is available on all sides and heat radiation kept at minimum and giving the operators an easy workable environment and ventilation. The materials will be sufficient structural thickness of mild steel angles neatly coated with metal primer and epoxy paint to withstand sea corrosion Smoke less burner unit with all accessories:-Oil flow rate range (100-2500) B/D.-GOR range (200-1000) SCF/D.-API range (14-30).-AIR supply: pressure (50-150) psi, flow rate (350) ft3/min.-Water supply: maximum pressure (300) psi, flow rate water (1800) B/D.-Pilot light: propane gas or gas & oil.-Ignition: supply (400 V, 3 phase +N +T, 50 Hz) & (work at 55 c).-Rotation device: one swivel joint allowing rotation of (75) each side of boom center line.-Connections: (oil 2 in-L.P.) & (air 2 in-L.P. equipped with WECO hammer union fig. 602 – (water 2 in-L.P. equipped union fig. 602). -Pilot gas 1/2 in-L.P. • Installing a readymade concrete base (Precast) with Height 30 cm above the ground and 20 cm below the surface of the earth. • The dimensions of the base are increased by (2 meters) from the edge of incinerators • The rest of the accessories in all the trends even allows the worker directly feeding and maintenance work, cleaning and move easily taking into account the tendencies of the base toward the door for drainage of water.• The floor coating must be high-quality epoxy paint.• Install anti-rust and heat Umbrella of brick and steel (pyramid shape) of (5) meters height above the ground which installed with the edge of the concrete base by thick galvanized columns • This umbrella Cover the site furnace and allow bringing the chimney• The site is surrounded by an iron fence (sheet metal) 3 meters height from the surface of the earth in order to protect the incinerators from dust storms • The iron fence must have a 5 meters Width gate • Automatic anti-rust and heat electrical circuit must be provided • The furnaces are highly efficient, emissions-free, safe, and environmentally friendly and have capacity of not less than 3,000 kg of materials and the rate of burning at least 400 kg / h• The method of feeding the furnace through a side slot or from the top and the emission of the smoke is completely prevented.• a furnace Must have two rooms, one of them is the main room of not less than the “5” stoves to the process of burning materials and other secondary room of not less “2” stoves to burn resulting gas from the first process as well as the chimney• The main component of the body of the furnace is stainless steel box, the thickness of not less than 7 mm with a layer of zinc phosphate plated with aluminium reflector to heat• the thickness of the door of 150 mm and a hardness of not less than 170 kg / m 3 to be burnt, automatic comprehensive remote system.• Furnaces must be destructive enough to burn and incinerate the material which mentioned previously • furnaces must have certificates are supported global enterprises and government competent for environmental protection In the country of origin or the General Presidency of Meteorology and Environment Protection in Saudi Arabia• The oven can work for 24 hours so as to allow for the burning of materials for a period of not less than 12 consecutive hours and the remainder for cooling and provides full fuel tank with a capacity of 1000 L to turn on the oven.• Must have an automatic ignition and diesel is used• a furnace has the ability to withstand extreme temperatures up to “130o c And also, it guarantees continuous operation of which can be utilized for 24 hours with the ability to remove residues during the work of the oven, Insulating layer of calcium must be present in the rooms with Thickness not less than 50 mm and a wall thickness of 100 mm • Isolation of burning room: the space between the walls& nbsp;must be of the “stainless steel”. In addition, burn room must fill with Thermal insulation material.• Ensure that the combustion of materials emitted in the secondary room should be at least two seconds period and the room is lined with high-density ceramic fibbers• Incinerators must contain a system for processing (purification) gasses before emission of the smoke.• Incinerators must have the capacity of self-cooling after the end of the daily operating period.• Incinerators must have chimney not less than “4 meters” height from the surface of the oven, also, it must be thermally insulated and non-rust able, and must also be removable, installation and tide default.• Electrical capacity required “220/ 380-volt “60 hertz• Incinerators must be fitted with a control panel of the electronic keys to monitor all the necessary indicators of activation keys, as well as start-up and switch off so as to be isolated inside a metal box with the presence of the following:Alarm Sensor in the event of (crashes “burner” or purification device or heat leakage or internal connections and wiring)Monitors for the temperature of the roomsAerosols Filter indicators/ monitorsRoom temperature sensors Indicators for furnaces and index overloadTimer for Extinguish the oven automatically depending on the time required. • All equipment must be highly resistant to external conditions such as high temperature (50oc) • All doors must have special lock are not allowed non-persons appointed to work.• Providing fire extinguisher for each site with a capacity of 10 kg at least9.Metal fuel tank from black steel (capacity not less than 2500 litres) and shall be installed at the incinerator Room. The tank shall be provided with all necessary fittings including fill, vent, drain and overflow line, level indication and access for inspection and maintenance. Level switches shall be provided for the following services. (a) Low level alarm (b) High level alarm (c) Low level start of transfer pump (d) High level stop of transfer pump
Industrial MultiWaste Incinerator System
Design, installation and commissioning of multi industrial waste incinerator. Capacity: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with dual chamber system)1st chamber-870 Deg.C – 900 Deg.C2nd chamber-1000 deg.C – 1200 Deg.CIncinerator should have following criteria:radiant temperatureAdvanced gas treatment system to avoid emission of toxic gases (scrubbing system).Low consumption high efficiency compact automatic burning system.Low running and maintenance costsFully automatic and simple to operate control panelAfterburner PreheatDense refractory concrete lining rated at 1600 CSolid Hearth to allow maximum BurnoutLarge Top opening lid for easy loadingWide door for ash removalOptional Stainless Steel CasingHeat recovery optionIt has special metal seal structure, refractory, bricking art, air distribution of multi-stream circling and advanced end-gas treatment without second pollution. Provide automatic control for users. The system should passed appraisal, fill up national blank and become substitute for import products. It should have notable economic and social benefit. 1). Ignition transformer 2). Ignition rod 3). Digital temperature indicator 4). Temperature controller variable 5). Thermo couple (heat sensor) 6). Flame detector 7). U.V. Sensor 8). Electromechanical Solenoid valve 9). Low and high fire control governor. 10). Eye hole for visual indication. 11). Venturi Scrubber filtration system for smoke control emission. 12). Liquid spraying nozzles with the capacity of 25 % (20 nozzles).
Incinerator Secondary chamber gas residence time
Secondary chamber gas residence time shall be minimum 1 second at 1050 oC.Primary Chamber:Type: Static Solid HearthMaterial of Construction: Mild Steel, 5mm thickRefractory thickness: approx.115mm thickMaterial: Refractory bricks confirming to international standard.Temperature resistance: 1400 oCInsulation thickness: approx.115mm thickMaterial: Insulation bricks confirming to international standard.Waste Charging: Manual & Automatic waste charging.Ash Removal: Manual/automaticSecondary Chamber:Type : Static Solid HearthMaterial of Construction: Mild Steel, 5mm thickRefractory thickness: approx.115mm thickMaterial: Refractory bricks confirming to international standard.Temperature resistance: 1400 oC.Insulation thickness: approx.115mmMaterial: Insulation bricks confirming to international standard.Waste Charging: Manual & Automatic waste charging.Emergency Stack:Type: cylindrical, top mounted on venturi ejector.Material of Construction: Mild Steel, 3mm thick.Refractory: 75mm thick castable.Insulation: 25mm thick castable.Quencher:Material of construction of outer body: Mild Steel refractory lined from inside.Shall have water circulation system with centrifugal pump.It shall have to reduce flue gas temperature before venturi scrubber.Shall provide pump motor of suitable capacity.Air Pollution Control Device C Venturi ScrubberType: High pressure jet type.MOC: Stainless steel C 316L.Temperature at the outlet: 78-80 oCScrubbing Media: Water with 5% causticRe- Circulation Pump for Venturi ScrubberType: CentrifugalApplication: PP/SSPiping : PPRDroplet Separator & Re-Circulation Tank (Integral)Type: CyclonicApplication: To separate water droplets from flue gasesMaterial of Construction: Mild Steel Rubber lined 3mm thickI.D. Fan:Type: High pressure centrifugalMaterial of Construction: Stainless steel 304, impeller and mild steel rubber lined castingDrive: BelCombustion Fan:Type: CentrifugalModulation: Manual damper controlMaterial of Construction: Mild SteelDrive: Direct drive
HICLOVER Environmental Protection
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction […]
Specifications for Double Chamber and Mobile Incinerator
Specifications for Double Chamber Incinerator: Primary Combustion ・ The primary combustion chamber shall be accepted as the primary combustion zone. ・ The minimum combustion temperature of the primary chamber shall not be less than 800 degrees c Secondary Combustion ・ The residence time in the secondary chamber shall not be less than 2 […]
Technical specification for burning machine
Technical specification for burning machine 1.Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by custom authority to burn different kinds of drugs. All need equipment must be provided. 2.Warrantee: booth systems must be provided with 3 years warrantee from the date of acceptance. All needed spare parts, preventative maintenance repair and corrective maintenance must be included in the cost and provided to the customer. 3.All needed electric and water connections must be provided. 4.Both systems must be of high quality and must be environmental friendly. 5.The capacity of each system should be up to 100 kg/hr. 6.The system must have automatic feeding. 7.Each system must consists of two burning rooms, one primary room for burning the drug and another room for burning the gases that emit as a result of primary burning. 8.The oven must be made of steel that is rust resistance and with thickness not less than 6 mm. 9.Each system must be of high efficient in burning different kinds of drugs, and should have 99.9% efficiency for burning organic materials. 10.Waste products should not exceed 5%. 11.System must have automatic ignition system. 12.System should use diesel (HSD) as fuel and should not consume more than 8 to 10 lt/hr . 13.Each system should be provided with fuel tank of size adequate to operate the system for one full day. 14.The temperature in the primary room should be 850 C ± 50 C. the system should also be capable to operate up to 1050 C ± 50 C. the system should be capable of continues operation and should be provided with cement layer insulator with adequate thickness. 15.Oven should be provided with heat insulator to allow easy operation. 16.Gas should remain in the secondary room for not more than 1.5 second.
SPECIFICATIONS OF THE MEDICAL BIOLOGICAL WASTE INCINERATOR
SPECIFICATIONS OF THE MEDICAL/BIOLOGICAL WASTE INCINERATOR It should be a three chambered incinerator The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other operational requirements. The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc. It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan. The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion. In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere. A system for continuous emission Monitoring and Environmental Monitoring. A mechanism with which to treat the waste water before discharge into the sewerage system. Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the chambers during operation. Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney). High power electricity and emergency generator connection for automated ignition purposes. The chimney should be tall enough and be at least one meter above the tallest building in the vicinity. The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire hazards. Capacity of 250. Other Requirements Training of all the personnel involved in health care waste (HCW) management. The Automatic Feeding system of the Incinerator Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber. An Automatic bottom ashes discharge system.
MEDICAL/BIOLOGICAL WASTE INCINERATOR
SPECIFICATIONS OF THE MEDICAL/BIOLOGICAL WASTE INCINERATOR It should be a three chambered incinerator The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other operational requirements. The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc. It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan. The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion. In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere. A system for continuous emission Monitoring and Environmental Monitoring. A mechanism with which to treat the waste water before discharge into the sewerage system. Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the chambers during operation. Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney). High power electricity and emergency generator connection for automated ignition purposes. The chimney should be tall enough and be at least one meter above the tallest building in the vicinity. The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire hazards. Capacity of 250. Other Requirements Training of all the personnel involved in health care waste (HCW) management. The Automatic Feeding system of the Incinerator Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber. An Automatic bottom ashes discharge system.
a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner
The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimum control of the operating conditions and incorporate a high capacity thermal oxidizing secondary chamber. It should be designed to retain the exhaust gases, for at least 2 seconds to ensure the unit’s effective destruction of the combustion products. i. Waste type Health care waste ii. Waste density 125 to 350Kg/M3 iii.. Waste Calorific Value 4000 KCAL/Kg iv. Moisture content 10-25% v. Estimated ash residue 5-10% vi. Nominal capacity 50Kg/hour batch load vii. Secondary chamber 2 seconds @ 850°C The primary combustion chamber is the main structure of the incinerator, fabricated from mild steel plate and stiffened with rolled steel sections. It is carried from the floor level on a substantial steel support frame. Internally the shell is lined with calcium silicate insulation and a hot face combination of super duty brickwork or high strength castable. The primary combustion chamber must ensure minimum exit temperature is not less than 850°C. One Manual Load Incinerator comprising: • Manual Loading door • Horizontal solid hearth, refractory lined primary combustion chamber. Approximate dimensions 800 mm diameters x 2100mm long • Full sized bulk load/ash removal door • 1 off diesel-fired ignition burner — temperature controlled • 1 off combustion air supply fan and distribution system, automatic control […]
Evaluation of Vendor offer for Solid Sludge Waste Incinerator
Square Textiles Division Evaluation of Vendor offer for Solid Sludge Waste Incinerator Criteria Our Requirement Vendor Brand/Manufacturer Nanjing Clover Local Agent N/A Country of Origin China Offer Reference 2016072701N211 Technical Details Model of Incenarator WS-100 Capacity 100 Kg/Hr Type of Waste Used “1. Sludge of ETP 2. Waste Fabric and Yarn 3. Kitchen Waste (includes dry objects and polythene bags) 4. Paper/Carton 5. Spinning Mill AC dust/ Micro Dust” Line Diagram PCC-SCC-Chimney-Water Tank-Spray Scrubber-Fog & Water Separator-ID System-Chimney No of Combustion Chamber 2 2 Temperature Range at PCC 800 C 800°C-1000°C Temperature Range at SCC 1000 C 1000°C-1200°C Useful Life of Incinerator 10 Years Operating Hour/Day Continuous (24 Hours) 16 Total Power Consumption (KW) Space Requirement for the plant (L x W x H) Primary Combusion Chamber Chambers Construction Material Steel Type of Refractory Material Refractory Lining Thickness Conductivity of Refrectory Materials Constituents of Refrectory Materials Volume of Primary Comustion Chamber […]
Incinerator Requirements
The requirements for a unit are as follows: 1. chemical agents to be utilized: • 10% heptyl (unsymmetrical dimethylhydrazine) water solution, • heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m³ concentration, • 10% azotic (nitric) acid water solution, • azotic (nitric) acid vapour with concentration up to 1.1 kg/m³; 2. neutralization method: thermal decomposition; 3. neutralization temperature: +800˚C to +1200˚C; 4. performance: • vapour capacity: 70 to 200 m³/h, • water solution capacity: 50 to 500 l/h; 5. inlet pressure: up to 2 bars; 6. automatic control system; 7. overall dimensions shall allow for mounting the unit on a vehicle chassis. We have viewed through your product range and, perhaps, YD15C- YD30model or YD50- YD500 model will suit our application best. If so, please confirm this. If not, what model, in your opinion, can meet our requirements better?
TECHNICAL SPECIFICATIONS FOR NAMAPA HOSPITAL,INCINERATOR 20KG
INCINERATOR 20KG General Specifications 6mm plate steel sheel construction 11cm 1400 º C Refractory L iner Temperature controlled Burners Secondary combustion Burners Interlock Switch on Load Doors Separate Ash Door One Second secondary Residence @ 1000 º C 400 ° C Silicone Based Paint Finish. Alloy Temperature Sensor Factory wired and tested Capacity-20 kg / hr Primary Chamber-1607 L Hearth Area-1:36 sq. m Secondary Chamber-694 L Primary Burner (oil)-420,000 btu Secondary Burner (oil)-900,000 btu secondary Combustion-1/6 hp Exhaust Stack-46cm x 6m Electrical Service-220/50 Weight System-5.700 kg Dimension “D”-152cm Load Port Height- 60x 60 cm Ash Port Height -36 x 36 cm Electrically operated incinerator In a simple design with a metal steel drum electric. including: A cage for receipt of biomedical waste; A combustion chamber with fireplace with a filter to retain ashes; A cover; An air supply; A turbine allowing the supply of the air. Combustion temperature: 1800 ° C. Compliance with European standards. Comes with all necessary accessories
Large Incinerator Industrial Unit – Waste Types
Large Incinerator Industrial Unit – Waste Types Approx Burn Rate of 1000 KG/Hour – 18 hours/Day. Cap 7 to 9 Cbm Auto Continuous Feeder* Control Panel Stand Fuel Tank Pollution Control & Monitoring System Service Packs Static Loading Mechanism* Venturi Scrubber Quantity 1 set Capacity 200 kg/hr Loading capacity 400-500kg/batch Overall Width 8,500mm Overall Length 10,000mm Overall Height 3,450mm Fuel Type Diesel Overall Fuel Consumption Exhaust Smokeless Odorless Quantity 2 sets Capacity (200 kg/hr)/set Diameter 1,912mm Height 2,962mm Furnace Volume 5m3/Set Furnace Exit Temperature 500-1000 deg C. External Material Steel Plate 6t, channel Internal Material Fire Proof, CT-160 Insulation Ceramic Wool 25T, Insulation 50T Access Hole/Door Burner 1 set 80,000 kcal/hr capacity […]
INCINERATOR DESCRIPTION
The Model is for up to 300kgs capacity per batch load and will burn at around 55kgs per hour. The unit has top loading design and has a heavy duty refractory cement lining for maximum heat retention. Unit have large top lid for easy loading, and specially designed front ash door, for ash removal. This unit operates at over 1100°C in the primary chamber to ensure complete combustion. This model also benefits from a heavy duty secondary chamber and burner which ensures a complete re-burn of any smoke and emissions and a 0.5 second gas retention time. PRIMARY CHAMBER Heavy-duty steel casing High quality refractory lining and insulation Large full size top load door and liquid retention sill 1 x diesel oil fired ignition burners operated on/off SECONDARY CHAMBER Heavy-duty steel casing High quality refractory lining and insulation 1 x diesel oil fired ignition burners operated on/off CHIMNEY Heavy-duty stainless steel casing 1.5m length 0.6m refractory lined stack CONTROL PANEL Control of 1 burner Timer control 0- 12 hours Integral fan timer control Temperature Monitoring Thermostatic Control Automatic Control Cycle time set up ANCILLARIES Operating and maintenance manuals Spares list CONTAINERISATION incinerator fully installed inside of 10 ft ISO certified container 3,5 kwA electricity generator, 1000 litres fuel tank Incinerator mounted on the silenblock cushion.
multiple diesel fuel combustion chambers Incinerator
*External diameter at base 6ft 1.8m *External diameter at top 4 1/2ft 1.35m *Internal diameter at base 3ft 0.9m *Internal diameter at top 3ft 0.9m *Thickness of wall at base 18cm *Thickness of wall at top 9cm *Perpendicular height of wall 4ft *Height of Iron bars from grate above ground 1ft Material Required *Puddle swish *5 or 6 Iron bars about 4 1/2ft 1.35m long each *Quantity of large stones for foundation *2 empty kerosene tins for making vent holes *2ltrs of coal tar *2 brushes *Foundation 1ft-1 1/2ft deep is dug *Filled with large stones and puddle swish to ground level *Empty kero tins are next placed into position where the vent holes are to appear *Wall 1ft high is built with puddle swish *Iron bars are put in position leaving a space of about 2cm-3cm between the bars 4ft 1.2m to be reached *Wall plastered smooth multiple diesel fuel combustion chambers Performance capacity 120kg/hr GRE 1.25 for HCRW 96kg/hr GRE 1.25 for general waste. 40kg/hr GRE 3.00 for plastic Waste type: health care risk waste and general waste Chimney stack Chimney: 3.5mm mild steel Height from base: 11m and if there are buildings within 30m of the incinerator, chimney must extend at least 3m above the apexes of all the roofs of such buildings Diameter of chimney at top: 430mm Weight of stack: ± 500kg case and stack be painted with 400 °C heat resistant black paint Burners 1st chamber 850 oC -900oC 2nd chamber 1000oC Variable speed combustion air blowers Primary chamber volume ±1.05 cubic metres Mixing chamber volume ±0.30 cubic meters Settling chamber volume ±0.89 cubic meters Weight excluding chimney ±6 400kg at manufacture Firing tools supplied: Hoe, poker and rake Dimensions Length ±2 125mm Width ±1 890mm Height ±2 125mm Extra width for burners […]
Incinerator 300 kg/hr Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day)
Incinerator 300 kg/hr Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day) (Power Supply 380V, 50Hz, 3Ph) Incinerator 450 kg/hr Burn Capacity (min. 1800 kgs. Waste Feed Capacity per day) (Power Supply 380V, 50Hz, 3Ph) Incinerator main unit main body (primary chamber, secondary chamber, mix-combustion chamber Filter Chamber Chimney PLC Panel Oil Tank Combustion burner Wind Tube Oil Tube Filter brick Ash clean tool Blower Furnace gate One bag chamber maintenance material Feed Capacity 600-1200 kg per feed Burning Rate Min. 300 kgs per hour Burning Time per Feed 2-4 hours Voltage 380V Power 1.48Kw Frequency 50Hz Fuel Natural Gas or Diesel Oil Fuel Mode Manual Fuel Consumption (Oil) Max 40 kgs per hour Fuel Consumption (Gas) Max 44 m3 per hour Waste Combustion Chamber 2400 liters Post Combustion Chamber 1200 liters Oil Tank Capacity 500 liters Chimney 10.0 M Chamber Material Firebrick, Refractory Concrete Max. Heat Value 340,000 Kcal per hour Operation Technical Specification Solid Chamber Temperature 800 Deg. C – 1000 deg. C […]
waste incinerator overview
Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. to 600kgs/Hr., up to 10ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. Key Features: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day. * New Design for pet animal cremation business. * One year warranty on incinerator and parts in stock.
INCINERATOR QUESTIONNAIRE
1. Type of waste: Trash 2. Any other type: 3. Quantity of waste generated per day in kg: (50 Ton per day) SOW 4. Duration – incinerator will be used per day: (Minimum 12 hours) SOW 5. Approximate moisture content: 6. Local incinerator operating and emission standards: US-EPA 7. What is the height of the chimney required: Not known 8. Fuel proposed to be used: Deiseal Oil 9. Availability of power and type: 220 or 110 10. Details of space available: Plenty of space 11. Do you require an automatic loading system: [**] Yes [**] No 12. Do you require a gas scrubbing system: [**] Yes [ ] No 13. How soon do you require the system to be delivered: 30 14. Any other specific requirements: 15. Nature: (Solid/Semi-solid/Liquid) Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system Imputing door Mouth Width (mm): 760*760 (approx.) Chimney External Diameter (mm): 300 ± 10 Combustion Improver Device: 0.11kw, Fuel consumption: 7kg/ hour (max) Re-Burning Device: Oil consumption: 5kg/h, 0.37kw, Oil consumption: 10-20kg/h Voltage: 380v/220v AC, Warranty: 1 Year, 50 Hz
Medical waste incinerators bio Capacity incinerator medical waste to high combustion temperature
Medical waste incinerator bio Capacity incinerator medical waste to high combustion temperature With a smokeless device to protect the environment and with two combustion chambers equipped with gas burners or oil -incinerator to burn large volume pieces of 70 cm deviation: Automatic Control System -destructive capacity from 20 to 30 kgs First-room / Temperature = 900 ° C combustion 2nd bedroom / Temperature = 1200 ° c afterburner -burner = 116Kw Burning Rate: 50Kg/Hr Feed Capacity: 150Kgs Primary Combustion Chamber: 900 Litres Secondary Combustion Chamber: 300 Litres Mix Combustion Chamber: Yes Smoke Filter Chamber: Yes Feed Mode: Manual Power: 0.7kW Fuel Type: Diesel/LPG/Natural Gas Internal Dimension: 120 x 90 x 85cm (Primary Chamber) External Dimensions: 200 x 160 x 310cm (Without Chimney) Burning Efficiency: >98%
Design standard Multiple chamber incinerator
Waste type organics domestical waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length Width Height Extra width for burners At least 3000mm Loading door opening Minimum 700mm x 600mm Hearth area 5.00square meters Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated Primary chamber volume At least 3 cubic meters Mixing chamber volume At least 1 cubic meters Settling chamber volume At least 3 cubic meters Weight excluding chimney 15, 000kg at manufacture Firing tools supplied Hoe, Poker and rake
diesel Fuel incinerators
diesel Fuel incinerators 16. The supplier must provide necessary information for the best of the installation. This incinerator with “PYROLYTIC” combustion must have: 17. A combustion chamber of waste: Perfectly tight door for the manual loading of waste. The loading should be manual, batch load. A burner of lighting which the use is limited to the ignition of waste. Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory. The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal. Composition of the refractory; Refractory concrete: Thickness :>100mm Nature: 42% of Al203 Insulate in fibrous panels: Thickness: >75mm Nature: Calcium silicate. Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 18. A chamber of post combustion of gases A burner of combustion of gases, A device of injection of air allowing a total re-combustion of gases, A device of air inlet of cooling of waste gases, A sheath of evacuation of the gases burnt, Carcass in strong sheet steel with support of connection Composition of the refractory; Refractory concrete: Thickness :>150mm Nature: 65%% of Al203 Insulate in fibrous panels: Thickness: >85mm Nature: Calcium Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. A secondary injection of air to ensure perfect oxygen content.
Hot Medical Waste Disposing Machine Burn rate per hour: 250 -300kg/hr
Incinerator should be smokeless, odourless combustion and it should be made by high-quality cast, insulation, and steel plate as well as minimum generation of dust. Moreover the incinerator should be corrosion resistant. Type Pyrolytic:- Hot Medical Waste Disposing Machine Operation Condition 8-16 Hr /day Controls Built in data recording Incinerator /Primary Combustion Chamber Type: continuous loading Capacity/Burn rate per hour: 250 -300kg/hr Temperature: 900-1200 oC Material: External- 3 layers Internal lining: a fire proof material of pre-fired refractory bricks with Aluminium lining, […]
SPECIFICATIONS OF A DIESEL FIRED INCINERATOR
SPECIFICATIONS OF A DIESEL FIRED INCINERATOR Incinerator type: Animal waste incinerator Load Capacity minimum: 1500 kg Burner fuel type: Diesel Burner fuel rate max.: 20-25 Liter diesel/ per hour Burners minimum: 3 Burning rate minimum: 200-300kg/per hour Furnace bar area minimum: 2 м3 Fuel tank capacity minimum: 300L Main chamber burning temperature min. 1100 0C Afterburner chamber burning temperature min. 1300 0C Power supply 220V Incinerator items and electrical appliances should be weather proof and humidity resistant within the range of 30-90 % Incinerator should be compliant to the environmental protection rules in accordance to national legislation Maximum dimensions C Length C 5m, width C 3.5m, height C 5m INCINERATOR, DIESEL, FIRED. Specifications Indicate if item offered complies with each specification. 1.1 General description The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimum control of the operating conditions and incorporate a high capacity thermal oxidizing secondary chamber. It should be designed to retain the exhaust gases, for at least 2 seconds to ensure the unit’s effective destruction of the combustion products. For the Supply, installation & commissioning of a Medical Waste Incinerator as detailed below: i. Waste type Health care waste ii. Waste density 125 to 350Kg/M3 iii.. Waste Calorific Value 4000 KCAL/Kg iv. Moisture content 10-25% v. Estimated ash residue 5-10% vi. Nominal capacity 50Kg/hour batch load vii. Secondary chamber […]
Incinerator smokeless and odourless combustion-hot medical waste disposing machine
Incinerator should be smokeless, odourless combustion and it should be made by high-quality cast, insulation, and steel plate as well as minimum generation of dust. Moreover the incinerator should be corrosion resistant. Type of incinerator : Pyrolitic – hot medical waste disposing machine Operation Condition: 8-16 hr/ day Control: Built-in data recording Operating temperature: Incinerator /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: continuous loading, Top Loading Capacity/Burn rate per hour: 250 -300 kg/hr Material: External- 3 layers Internal lining: a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock Secondary Combustion Chamber: Type: horizontal/vertical Temperature: 1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment system : Capable of treating the flow of flue gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc Auxiliary device: Fuel cut-off device Waste feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time Chimney (Stack): Type: Vertical type height:>7 meter’ Material: Fireproof cast, stainless steel OUTPUT: GAS- SMOKELESS,ODORLESS ASH -Max <5% of original waste size Reduction of Pollutant gas SO2, HCL, HF and line particulate Emission standard: WHO/ European Test report for emission testing provided? Heat exchange mode: Automatic Accessories: All standard accessories for incinerator, including but not limited to loading system, heat exchangers, pollution control system, ash removal system, including ladder and oil tanker (2500litre capacity). Operating Environment: The incinerator is capable to operate at the altitude of 2400mt above sea level. (according to the site conditions) Power Requirement: 220 Vac single phase or 380 Vac three phase 4 wire system 50HZ Installation Testing and Commissioning : to be conducted by certified or qualified personnel. Supplier shall provide the following documentation User (Operating) manual in English. Service (Technical / Maintenance) manual in English. Certificate of calibration and inspection from factory. Fast moving spare parts: Supplier is able to provide fast moving spare parts with quantities as described in the price schedule or their equivalent. Training: Supplier is able to provide training on operation, management and maintenance of incinerators. Warranty […]
Destroy the wasted materials or chemical uses in pharmaceuticals
Destroy the wasted materials or chemical uses in pharmaceuticals through Primary & Secondary combustion Chamber’s with working temperatures are 850° C & 1100° C or 1200° C & 1400° C. The incinerator design must meet with ISO, OSHAS, Emission Standards, Norms and Guidelines. The incinerator design must have heat recovery system and low fuel consumption system while incineration. The machine should have following features in its respective parts – Feeding system Automatic/ and manual control system Automatic heating control system Easy maintenance Outdoor type IP grade material Heat recovery system Low fuel consumption system Combustion chamber dual type with heat recovery system Burner system with economizer / low fuel method Scrubbing system as per regulation Easy dust collecting system Chimney (height 50 meter) Record printing system Incinerators to be suitable for the professional disposal of clinical & medical waste / garbage with a higher load capacity in the range of approximately 1000-1500 Kg. The durable, self-contained incinerators shall offer an effective and highly efficient, safe disposal and to be manufactured according to applicable international directives, e.g. CE, EU, etc. Type of Fuel: Diesel or Petrol or Natural Gas. Temperature controlled, efficient burner for optimum fuel economy. Units to be pre-assembled, pre-piped, pre-wired and tested before transport / export. Within the framework of an environmental and medical equipment & technology consultation and joint purchasing, this Procurement Bureau invites applicants for pre-qualification in the aim of primarily selecting capable companies to bid for the above tender.
Mobile Diesel Fired Incinerator in container
Mobile Diesel Fired Incinerator in container, supplied with the following specifications: complete with constant ventilation fans for extraction, factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. Fully containerised mobile waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner b. Dedicated independent fan system, damper controlled. c. Thermostatic Sensor d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor c. Minimum Temperature of 1100 deg.C as per WHO guidelines. d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play c. Threezone monitoring of: i)Primary chamber ii) Secondary chamber iii) Hot hearth d. Digital display e. Burner on-off indication lights f. Timer Chimney: a. Mild steel painted red b. Refractory insulated with 50mm of insulation. Unit Dimensions: 1840mm x 1 ‘1 50mm x 1950mm high. Safety: […]
200 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS
1) Policy – Waste disposal management shall be taken special note to prevent hospital infection. – Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site. 2) Waste Disposal Plan a) Classification – Medical wastes in hospital are classified as follows; Infections Waste Specially-controlled waste […]
SOLID WASTE INCINERATOR Feeding Capacity 200 to 220 Kg
Burn Rate * 60 Kg / hr Ingredients to be burned Cotton, Rubber, PVC Sheets, PE Gloves, Oil, Plastic Bottles, Paper etc. Chambers * Dual Chamber. 1: Primary Controlled Air 2: Secondary Excess Air Temperature Monitoring Required Temperature Control to Primary & Secondary Chambers Required System Status & Alarms Required for all necessary parameters. Fittings & Accessories Complete Package is required ( Including Nozzles & Flanges etc.) Installation Requirements. As low as possible . Almost Plug & Play type. Dimensional Sketch, Operation & Installation Manuals. Required Off – Gas System Required Heat Insulation Required for indoor installation Delivery Karachi Sea Port – Pakistan The details of Components of incinerator is as follows: Component Name Features Range. Primary Chamber Temperature Required* 800 – 1000 deg C. Heating Source Natural Gas Secondary Chamber Temperature * 1100 – 1300 deg. C Heating Source Natural Gas + Propane or Fuel Oil as an additional source Off – Gas Residence Time 2 Seconds. Refractory Material Material * Alumina ( 56 – 80 % Pure ) Lining * SS 316L Life Span * 10 – 15 years. Rating Temperature […]
Fw: waste disposal range treatment capacity: 35 kg incinerator
Suitable models for required waste disposal range. Combustion efficiently per hour based on 08hrs operation and its fuel category installation method C Mobile type/ possibility of structured inside container / structured in permanent base Fuel consumption details consisting electricity Capacity: 20KG/Hr, Temp Range: 600 Deg. C C 1100 Deg. C Fuel Supply: Natural Gas/Diesel Dual Combustion Chamber Complete Scrubbing System (Dual Resultant Gas Washer), Dual Blower, Chimney Height: 8m Electric Supply: 220/240Volt, Single Phase Waste treatment capacity: 35 kg / h The combustion chamber is thick steel plate (3 to 10 mm ) with reinforcements, specially built . Front loading with watertight door mounted on hinges, locking screw wheel , flexible gasket and an insulating refractory lined . An internal lining of refractory concrete containing 42% of H2 03 (alumina ) and 100 mm thick walls. fibrous insulation panels made ??of calcium silicate with a thickness of 75mm . Automatic Burner ( diesel or gas must be specified in the order ) with flames diving in one piece monoblock with an electronic ignition system , permanent ventilation control valve and isolation valve. combustion floor made ??in carborundum , preventing binding of glass and slag. Equipped with two (02) chambers Fuel: Gas or butane gas Power supply: 220 V 50 Hz single-phase Capacity 100 Kg (0.18 m3) Electric starter ・ The room dimensions are 6.64 m width x 6.61 m length x 6.03 m height at lowest point/per one incinerator. Are these dimensions sufficient for complete one medical incinerator 150 kg/hours (1.5ton/day). ・ Please, provide complete data about chemical consumption required for waste incineration, gas emission treatment ,liquid waste and generated soiled wastes handling and/or, treatment . ・ Please, confirm that the exhaust gases are treated by alkaline scrubbing (wet or dry).
Solid waste incinerator placed in a container
Solid waste incinerator, productivity 100kg/h placed in a container. Dimensions: 2,45×12,2m and 2,9m in height. Operates natural gas with the pressure of 0.005 MPa and consumption of 0,21-0,23 m3 per kg of waste. Installed power C 55 kW. Total 3 units. Fuel capacity:200l or more Incinerator has a temperature monitoring system in place Wet scrubber capable of removing sulpur dioxide in the fumes Water capacity of 2000l or more Incinerator temeprature above 950 degree celsius Incinerator used a dual chamber system for incinerator Capacity per hour at least 25kg 1. A combustion chamber : a. watertight door for manual loading of waste. b . A burner start is limited to inflammation of waste . 2. A camera post-combustion gases : a. burner combustion , low power . b . An injection device air for total recombustion of the gases . c . An input device cooling air of the combustion gases. d . A smoke evacuation duct . 3. A control panel ensuring complete combustion cycle . The incinerator meets as indicated on waste incineration . They will not burn plastics, packaging except that the amount so small that gases need not receive any treatment, secondary combustion chamber to 1100C handles everything .. Water waste incinerator, productivity up to 3m3/h and placed in a modular building. Dimensions: 8,2×5,9m and 5m in height. Operates natural gas with the pressure of 0,016 MPa and consumption of 0,35m3 / kg of drainage. Installed power C 35 kW. Total 1 unit.
Hot Medical Waste Disposing Machine
Type Pyrolytic:- Hot Medical Waste Disposing Machine Operation Condition 8-16 Hr /day Controls Built in data recording Incinerator /Primary Combustion Chamber Type: continuous loading Capacity/Burn rate per hour: 250 -300kg/hr Temperature: 900-1200 oC Material: External- 3 layers Internal lining: a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock Secondary Combustion Chamber Type: horizontal/vertical Temperature: 1200-1400 oC Residence time of gases : >2 seconds Material External- Low thermal mass insulation 14-30 oC Internal lining: a fire proof material of pre-fired refractory bricks with Aluminium nettle lining, resistant to corrosive waste or gas and to thermal shock. Ash Handling System Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash. Flue gas treatment system Capable of treating the flow of flue gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc. Auxiliary device: Fuel cut off device Waste feeding mechanism Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800L at a time Chimney (Stack) Type: Vertical type height: 7-10 meters Material: Fireproof cast, stainless steel Wet scrubbing system Vertical sprat tower with baffles or packing inside Gas emission Reduction of Pollutant gas SO2, HCL, HF and line particulate OUTPUT ASH -Max <5% of original waste size GAS- SMOKELESS,ODORLESS Emission standard WHO/ European Test report for emission testing Must be provided […]
Containerized Mobile Incinerators
○ Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to […]
Containerized Mobile Incinerator
○ Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to […]
HICLOVER Waste Incinerator
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction […]
what’s Incinerators
Incinerator, incineration equipment to burn material you want to burn. most of time, Incinerator for waste burning, including solid waste, liquid waste and gas waste. the Incinerator fuel including oil, gas, coal, wood, etc. the fuel function for start burn, keep waste burn or only keep burn itself to get […]
medical waste and general waste Incinerate
Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz Feeding: Automatic Ash/leftovers removal: Automatic Flue gas filtration system: Yes Quantity: Four (4) Type: Pyrolytic Use: For drugs With Chassis to be Mounted in truck/lorry May have a primary and secondary combustion chamber Must have a dilution chamber Capacity: 100 Kgs per hour Power Source: Diesel or Natural Gas or Liquified Natural Gas
system solutions for medical environmental protection
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction […]
Incinerator Ignition by Diesel
1. Petrol: diesel 2. Consumption: 8-10liter/hour 3. Capacity: to cremate (carrion and spoils) 350-400kg/hour 4. Temperature: 900-1350?C 5. Operation temperature: -30~40?C 6. Incinerator weight: 1800-2000 kg 7. Volume: 0.70-0.80m/cube 8. Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) 9. Trial able 10. Incinerator mouth size: 50-60cm (W), 65-75cm (L) Ignition by Diesel Minimum burning temperature 1200 Celsius Burning capacity of 20 Tons per day. Cooling by water Burn Rate 100Kg/h Shipping Weight 4000kg Capacity 300Kg MINIMUM Max. Burn out time 3.0 hrs. Avg. Ash Residue 3% Heavy Duty refracting lining to withstand 15000C Min. Operating Temperature 8500C Max. Operating Temperature 14500C Residency Time in Secondary Chamber 2 sec. Density Insulation (high) 22mm Avg. Fuel Consumption p/hr 7 to 9ltr Fuel Dual, box & Oil/Diesel Temperature Monitoring YES Auto ignition YES Refractory Casting (min.) 65mm Refractory Casting (min) 65mm INCINERATORS Biological waste disposal system (INCINERATOR). Incinerator must meet the following specifications: Combustion Capacity (kW) = 581 ±10% Combustion Capacity (kcal/h) = 500,000±10% Combustion Capacity – Solid waste IMO spec, (kg/h) = 100 IMO spec. (I/charge) Minimum Zero 0 to Maximum = 250 Combustion Capacity – Sludge oil IMO spec, (l/h) (at 20% water content) -66±10% Max. l/h (at approx. 50% water content) = 100 ±10% Weight approx. (kg) = 4,850 ±10%