what’s Incinerators

Incinerator, incineration equipment to burn material you want to burn. most of time, Incinerator for waste burning, including solid waste, liquid waste and gas waste. the Incinerator fuel including oil, gas, coal, wood, etc. the fuel function for start burn, keep waste burn or only keep burn itself to get […]

About Medical Waste

Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses. Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create a variety of health and environmental risks if not managed and destroyed in an appropriate manner. With years worth of experience in this sector, our medical range of incinerators are designed to cater for the economical needs of small clinics to the more demanding and specialized requirements of large hospitals in their waste management processes.HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste. Our products ensure efficient, clean and hassle-free disposal of medical waste is possible. The incineration of clinical waste including pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies , Drug Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste. ○Middle-Small Capacity(TS Model)※Main Features:— Double Combustion Chamber— Double Italy Burner–Burning Rate: 10-100kgs per hour–Combustion Chamber: 0.1M3-1.2M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Upgrade/Downgrade Burning Rate ○Large-Middle Capacity(YD Model)※Main Feature:–Three Combustion Chambers— Double Italy Burner–Burning Rate: 30-600kgs per hour–Combustion Chamber: 0.36M3-5.5M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner— Upgrade/Downgrade Burning Rate ● Service before and after Installation — Factory training for installation, operational and maintenance with free cost.— Online service support for installation, operational and maintenance with free cost.— Onsite installation, operational and maintenance training— Onsite service support after installation ● Spare parts supportHICLOVER now offers spare parts including:— Burners (diesel oil, LPG or natural gas)—   Element for burners— Fire ropes— Incinerator chamber maintenance materials— Air Fan — Temperature element—   Smoke filter brick—  Control box—  Other parts  Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Fax: +86-25-8461 0406 Website: www.hiclover.com  Email:[email protected]Email:    [email protected]  

500kg/day burn capacity incinerator

in acinerator with 300 kg/ hour by double filter wet and dry.Pet Dead Body Incinerator upto 80 kg ,gas operated is prefered. animal waste incinerator with capacity about 40Kgs. We will use this product to burn the animal corpses in normal way (not sick aninal).Could you please forward me quotation for […]

ecologically friendly incinerator

50 bed hospital and would like to have your recommendation for incinerator that can effectively handle the load of 50 bed hospital.Incinerator for burnable garbage (paper & organic) medium capacity (100/150 lts). Bio Medical Waste Incinerators, Capacity: 50kgs per hour Medical Waste Incinerator  Model  TS50 ( PLC ) with both option on […]

Incinerator capacity of destruction of 350 kg/hour

average daily slaughter is about 120 pigs. The Condemned material and byproducts from the abattoir for disposal is around 1000 kgs.daily one line incinerator for the destruction of hazardous medical waste. – Incinerator capacity of destruction of 350 kg/hour, calorific value of waste will be 13-25 MJ/kg [3,500 kcal/kg] and […]

factory installed Diesel Fired Incinerator

Estimados, agradecería una cotización por los hornos crematorios para mascotas modelo YD-30 / YD-50.Mobile Diesel Fired  Incinerator model supplied with the following specifications: complete with constant ventilation fans for extraction, factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 […]

small hospital waste incinetor

WASTE INCINERATOR –          150 KG/HR –          Compliant with EU rules, Directive 2000/76/EC –          Fuel type: Diesel –          Easy management and maintenance –          Temperatures: 850 deg C for municipal waste 1000 deg C for medical waste 1100 deg C for dangerous waste containing halogenated organic substances with content of chlorine or […]

containerised Hospital waste incinerator

One 40′ Standard – containerised Incinerator, and understand you can help us with the procurement of the same.Waste type or application  : General and Medicine Capacity kgs / hour             : 75 to 350 Hospital and Laboratory equipment. . One of our valued customer is interested to purchase a Hospital Waste […]

A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE

SPECIFICATIONS OF A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE 1.    Capacity of destruction in weight: 500 kg/h. 2.    It should be able to operate not less than 8 hours/day 3.    This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4.   […]

Hiclover bio waste incineration

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce. ※Main Feature:— Double Combustion Chamber— Double Italy Burner–Burning Rate: 10-100kgs per hour–Combustion Chamber: 0.1M3-1.2M3— Mobile Incinerator, Standard shipping containers, Easy to move/transport system— Free Installation, Pre-installed incinerator, Ideal for camps— Ultraviolet lamp sterilization inside Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm […]

incinerate biohazard waste

an incinerator which is capable of burning between 3 to 5 tonnes per day of mixed waste products, plastics, rubber, flammable putrescible waste, medical waste, rubber tyres, paper and cardboard, textiles, green timber waste etc. As some of the waste products will contain non-flammable solids, the incinerator should be capable […]

an animal cremator

an animal cremator for our business in malaysia.currently we are doing individual private cremation and mass cremation for pets as well as medical waste.an incinerator which is capable of burning between 3 to 5 tonnes per day of mixed waste products, plastics, rubber, flammable putrescible waste, medical waste, rubber tyres, […]

Double Chamber Incinerator on sale 50-200kgs per hour(in stock)

We supply Double Chamber Incinerator with primary chamber size average 1570Liters and burnning rate 50kgs per hour,100kgs per hour,150kgs per hour,200kgs per hour. the incinerators are now ready for shipping. Contact with us for quick respond: +86-13813931455 Main Product List per 01 set Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator […]

Containerized Mobile Type Medium Unit Waste Incinerator

Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50(PLC) Picture   Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Optional Upgrade Containerized Mobile Type Incinerator ISO 20′ Full Container Combustion Chamber 560L Internal Dimensions 1000x800x700mm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode […]

install a diesel fired incinerator

incinerate mainly pharmaceuticals ( all types of dosage forms … syrups, tablets, injectables ) medical consummabables, and also biological fluids … Capacity around 10 kg/ hour. install a diesel fired incinerator that can accommodate a batch load of up to 100 kg with a daily burning requirement of up to […]

incinerator manufacturer 200kgs/h

Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident time. Other specifications are as follows. A combustion chamber of waste: * Perfectly tight door for the manual loading of […]

50 to 60kg/hr and 100 to 120kg/hr diesel powered incinerator

50 to 60kg/hr and 100 to 120kg/hr diesel powered incinerator.1. Capability to Incinerate the Following Types of Waste: Household waste, glass, steel, aluminum cans and window extrudes, steel cans (crushed), timber, tires, white goods, plastic bottles, pressure packs, medical waste and quarantine waste. 2. Required Incinerating Capacity: Approximately 4,500 tons […]

For incineration, general and pathological incinerators

Main unit Application    For incineration, general and pathological Capacity      50 – 60 kg/h burn rate Type    Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                   Minimum 8 hours daily Operating temperature        From 850 0C to 1200 […]

250kgs per hour capacity waste incinerator

Incinerator Model TS250 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction  is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment.  Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on […]

Waste Incineration Treatment Model TS75(PLC)

Average 50-100 kg/hour Burn Rate   Items/Model TS75(PLC) Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Face Oil Paint 800℃ Combustion Chamber 768 Liters (0.768M3) Internal Dimensions 1200x800x800mm Secondary Chamber 384 Liters (0.384M3) Smoke Filter Chamber Yes Feed Mode […]

Two combustion chambers type incinerator

Load Capacity minimum:  1500 kg Burner fuel type:  Diesel Burner fuel rate max.:   20-25 Liter diesel/ per hour Burners minimum: 3 Burning rate minimum: 200-300kg/per hour Furnace bar area minimum: 2 м3 Fuel tank capacity minimum: 300L Main chamber burning temperature min. 1100 0C Afterburner chamber burning temperature min.  1300 […]

50-100-150-200 Kgs per Hour Solid Waste Incinerator on Sale

Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 sets oil burner, batch load  incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load […]

50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 sets oil burner, batch load  incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load […]

Containerized diesel fueled incinerators

Incinerator Type: Containerized, diesel fueled Burning Rate:100–120kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density Insulation:20mm High Refractory Casting:Minimum 65mm Heavy duty refracting lining to withstand:1500 oC Average burn out time :maximum:3 hrs Fuel type:Diesel Fuel Consumption in L/hr:7.5 to 9 Residence time in […]

Incinerator Video

Key Features: — Full range incinerator with Economized Small Scale incinerator,  Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator,  Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators. — System solutions […]

Containerized Incinerator Model CA30 from HICLOVER

Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator into shipping container(20′ container or 40′ container), with necessary Basic work, such as flooring, lighting, wiring, etc. Items/Model CA30 Picture Burn Rate Average 10 kg/hour Feed Capacity Average 30kg per feeding Control Mode PLC(Programmable […]

Diesel/LPG/LNG burning primary combustion chamber/primary combustion incinerator

Primary combustion Diesel/LPG/LNG burning primary combustion chamber/primary combustion zone Secondary combustion Residence time in the secondary chamber not less than 2 seconds Both primary and the secondary temperatures maintained until all the waste has been completely combusted Chimney Chimney with a minimum height of 4 meters above ground level Minimum […]

Medium Scale Solid Waste Incinerator

Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150(PLC) Principle Waste Incineration Treatment Burn […]

HIGH TECH MEDICALWASTE INCINERATOR

Incinerator model A Burn Rate 65kg/h minimum Weight (kg), please indicate: Secondary Chamber Gas Retention Time – 2 Seconds Fuel – Diesel/LPG/LNG, please indicate Power Supply for Control Box – 220V-240V 50Hz single phase Minimum operating temperature 850 °C, please indicate One year Spare Parts Package for complete maintainability 10m […]

50 KG/HR BIOMEDICAL INCINERATOR

Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour  Oil tank smoke filter chamber Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1000L Internal Dimensions 120x100x90cm Secondary Chamber 540L […]

Containerized Mobile Incinerator CA100

Incinerator Model CA100, Overview 100Kg/Hour Burning rate with Secondary burning Capacity This model is small-scale medical waste incineration equipment. Construction is dual/double  combustion chamber with 02 units oil burner, batch load incineration equipment. Animal feed  chamber is 560Liters (Model CA100). Primary & Secondary combustion chambers and smoke  filter chamber with firebrick […]

100-150kgs Burning rate with Secondary burning to be use in the hospital

Oil tank with 2000Liters capacity Items/Model TS150(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 100-150 kg/hour Feed Capacity Average 750kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Main Body Steel 8mm thickness Chamber Material High Alumina Fire Brick Wall, 1750℃ Rate Paint for outside face 800°C Rate Combustion Chamber 1570L […]

MEDICAL WASTE INCINERATORS

MEDICAL WASTE INCINERATORS for furnishing, installing, adjusting, and testing automatically controlled air medical waste incinerators having a capacity to burn 75 Kg/hour waste materials of biological and pathological nature. The process of incineration provides the advantage of volume reduction as well as the ability to dispose of recognizable waste and […]

Pet crematorium up to 200KG/day

Animal Crematory Incinerator Capacity: Average 80kgs per feeding Item Specification Model A900 Internal Dimensions 120 x 90 x 85 CM Suit for Animal Cat – yes Dog – yes Pig – small Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator […]

Animal Crematory with Movable platform & Auto. Door & Independent Position

Incinerator Model A1500, Overview This model is big-scale animal cremation equipment for big animals.  Construction is dual/double combustion chamber with 03 units oil/gas burner,  batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500).  Primary & Secondary combustion chambers and included mix-combustion chamber,  smoke filter chamber with firebrick and […]

Biological and Pathological Waste Incinerator

Biological and Pathological Waste Incinerator is defined as human and animal remains, such as organs, animal carcasses, and solid organic wastes from hospitals, laboratories, slaughterhouses, animal pounds, and similar sources. This type of waste contains up to 85 percent moisture and not more than 5 percent incombustible solids, and has […]