Evaluation of Vendor offer for Solid Sludge Waste Incinerator

Square Textiles Division Evaluation of Vendor offer for Solid Sludge Waste Incinerator  Criteria Our Requirement Vendor Brand/Manufacturer Nanjing Clover Local Agent N/A Country of Origin China Offer Reference 2016072701N211 Technical Details Model of Incenarator WS-100 Capacity 100 Kg/Hr Type of Waste Used “1. Sludge of ETP 2. Waste Fabric and Yarn 3. Kitchen Waste (includes dry objects and polythene bags) 4. Paper/Carton 5. Spinning Mill AC dust/ Micro Dust” Line Diagram PCC-SCC-Chimney-Water Tank-Spray Scrubber-Fog & Water Separator-ID System-Chimney No of Combustion Chamber 2 2 Temperature Range at PCC 800 C 800°C-1000°C Temperature Range at SCC 1000 C 1000°C-1200°C Useful Life of Incinerator 10 Years Operating Hour/Day Continuous (24 Hours) 16 Total Power Consumption (KW) Space Requirement for the plant (L x W x H) Primary Combusion Chamber Chambers Construction Material  Steel Type of Refractory Material Refractory Lining Thickness Conductivity of Refrectory Materials Constituents of Refrectory Materials Volume of Primary Comustion Chamber […]

Incinerator Requirements

The requirements for a unit are as follows: 1. chemical agents to be utilized: • 10% heptyl (unsymmetrical dimethylhydrazine) water solution, • heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m³ concentration, • 10% azotic (nitric) acid water solution, • azotic (nitric) acid vapour with concentration up to 1.1 kg/m³; 2. neutralization method: thermal decomposition; 3. neutralization temperature: +800˚C to +1200˚C; 4. performance: • vapour capacity: 70 to 200 m³/h, • water solution capacity: 50 to 500 l/h; 5. inlet pressure: up to 2 bars; 6. automatic control system; 7. overall dimensions shall allow for mounting the unit on a vehicle chassis. We have viewed through your product range and, perhaps, YD15C- YD30model or YD50- YD500 model will suit our application best. If so, please confirm this. If not, what model, in your opinion, can meet our requirements better? 

TECHNICAL SPECIFICATIONS FOR NAMAPA HOSPITAL,INCINERATOR 20KG

INCINERATOR 20KG General Specifications 6mm plate steel sheel construction 11cm 1400 º C Refractory L iner Temperature controlled Burners Secondary combustion Burners Interlock Switch on Load Doors Separate Ash Door One Second secondary Residence @ 1000 º C 400 ° C Silicone Based Paint Finish. Alloy Temperature Sensor Factory wired and tested Capacity-20 kg / hr Primary Chamber-1607 L Hearth Area-1:36 sq. m Secondary Chamber-694 L Primary Burner (oil)-420,000 btu Secondary Burner (oil)-900,000 btu secondary Combustion-1/6 hp Exhaust Stack-46cm x 6m Electrical Service-220/50 Weight System-5.700 kg Dimension “D”-152cm Load Port Height- 60x 60 cm Ash Port Height -36 x 36 cm Electrically operated incinerator In a simple design with a metal steel drum electric. including:  A cage for receipt of biomedical waste;  A combustion chamber with fireplace with a filter to retain ashes;  A cover;  An air supply; A turbine  allowing the supply of the air. Combustion temperature: 1800 ° C. Compliance with European standards. Comes with all necessary accessories

Large Incinerator Industrial Unit – Waste Types

Large Incinerator Industrial Unit – Waste Types                          Approx Burn Rate of 1000 KG/Hour – 18 hours/Day. Cap 7 to 9 Cbm  Auto Continuous Feeder* Control Panel Stand Fuel Tank Pollution Control & Monitoring System Service Packs Static Loading Mechanism* Venturi Scrubber Quantity 1 set Capacity 200 kg/hr Loading capacity 400-500kg/batch Overall Width 8,500mm Overall Length 10,000mm Overall Height 3,450mm Fuel Type Diesel Overall Fuel Consumption Exhaust Smokeless Odorless Quantity 2 sets Capacity (200 kg/hr)/set   Diameter 1,912mm Height 2,962mm Furnace Volume 5m3/Set Furnace Exit Temperature 500-1000 deg C. External Material Steel Plate 6t, channel Internal Material Fire Proof, CT-160 Insulation Ceramic Wool 25T, Insulation 50T Access Hole/Door Burner 1 set 80,000 kcal/hr capacity […]

INCINERATOR DESCRIPTION

The Model is for up to 300kgs capacity per batch load and will burn at around 55kgs per hour.  The unit has top loading design and has a heavy duty refractory cement lining for maximum heat retention. Unit have large top lid for easy loading, and specially designed front ash door, for ash removal. This unit operates at over 1100°C in the primary chamber to ensure complete combustion. This model also benefits from a heavy duty secondary chamber and burner which ensures a complete re-burn of any smoke and emissions and a 0.5 second gas retention time. PRIMARY CHAMBER Heavy-duty steel casing High quality refractory lining and insulation Large full size top load door and liquid retention sill 1 x diesel oil fired ignition burners operated on/off SECONDARY CHAMBER Heavy-duty steel casing High quality refractory lining and insulation 1 x diesel oil fired ignition burners operated on/off CHIMNEY Heavy-duty stainless steel casing 1.5m length 0.6m refractory lined stack CONTROL PANEL Control of 1 burner Timer control 0- 12 hours Integral fan timer control Temperature Monitoring Thermostatic Control Automatic Control Cycle time set up ANCILLARIES Operating and maintenance manuals Spares list CONTAINERISATION incinerator fully installed inside of 10 ft ISO certified container 3,5 kwA electricity generator, 1000 litres fuel tank Incinerator mounted on the silenblock cushion.

multiple diesel fuel combustion chambers Incinerator

*External diameter at base 6ft 1.8m *External diameter at top 4 1/2ft 1.35m *Internal diameter at base 3ft 0.9m *Internal diameter at top 3ft 0.9m *Thickness of wall at base 18cm *Thickness of wall at top 9cm *Perpendicular height of wall 4ft *Height of Iron bars from grate above ground 1ft Material Required *Puddle swish *5 or 6 Iron bars about 4 1/2ft 1.35m long each *Quantity of large stones for foundation  *2 empty kerosene tins for making vent holes *2ltrs of coal tar *2 brushes *Foundation 1ft-1 1/2ft deep is dug *Filled with large stones and puddle swish to ground level  *Empty kero tins are next placed into position where the vent holes are to appear *Wall 1ft high is built with puddle swish *Iron bars are put in position leaving a space of about 2cm-3cm between the bars 4ft 1.2m to be reached *Wall plastered smooth  multiple diesel fuel combustion chambers Performance capacity 120kg/hr GRE 1.25 for HCRW 96kg/hr GRE 1.25 for general waste. 40kg/hr GRE 3.00 for plastic Waste type: health care risk waste and general waste Chimney stack Chimney: 3.5mm mild steel Height from base: 11m and if there are buildings within 30m of the incinerator, chimney must extend at least 3m above the apexes of all the roofs of such buildings Diameter of chimney at top: 430mm Weight of stack: ± 500kg case and stack be painted with 400 °C heat resistant black paint Burners 1st chamber 850 oC -900oC 2nd chamber 1000oC Variable speed combustion air blowers Primary chamber volume ±1.05 cubic metres Mixing chamber volume ±0.30 cubic meters Settling chamber volume ±0.89 cubic meters Weight excluding chimney ±6 400kg at manufacture Firing tools supplied: Hoe, poker and rake Dimensions Length ±2 125mm Width ±1 890mm Height  ±2 125mm Extra width for burners […]

Incinerator 300 kg/hr Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day)

 Incinerator  300 kg/hr  Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day) (Power Supply 380V, 50Hz, 3Ph)   Incinerator  450 kg/hr  Burn Capacity (min. 1800 kgs. Waste Feed Capacity per day) (Power Supply 380V, 50Hz, 3Ph)   Incinerator main unit main body (primary chamber, secondary chamber, mix-combustion chamber   Filter Chamber   Chimney   PLC Panel   Oil Tank   Combustion burner   Wind Tube   Oil Tube   Filter brick   Ash clean tool   Blower   Furnace gate   One bag chamber maintenance material  Feed Capacity 600-1200 kg per feed Burning Rate Min. 300 kgs per hour Burning Time per Feed 2-4 hours Voltage 380V Power 1.48Kw Frequency 50Hz Fuel Natural Gas or Diesel Oil Fuel Mode Manual Fuel Consumption (Oil) Max 40 kgs per hour Fuel Consumption (Gas) Max 44 m3 per hour Waste Combustion Chamber 2400 liters Post Combustion Chamber 1200 liters Oil Tank Capacity 500 liters Chimney 10.0 M Chamber Material Firebrick, Refractory Concrete Max. Heat Value 340,000 Kcal per hour Operation Technical Specification Solid Chamber Temperature 800 Deg. C – 1000 deg. C […]

waste incinerator overview

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. to 600kgs/Hr., up to 10ton per day.  Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. Key Features: * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime.  * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day. * New Design for pet animal cremation business. * One year warranty on incinerator and parts in stock.

INCINERATOR QUESTIONNAIRE

1. Type of waste: Trash   2. Any other type: 3. Quantity of waste generated per day in kg: (50 Ton per day) SOW 4. Duration – incinerator will be used per day: (Minimum 12 hours) SOW 5. Approximate moisture content:  6. Local incinerator operating and emission standards: US-EPA  7. What is the height of the chimney required: Not known 8. Fuel proposed to be used: Deiseal Oil  9. Availability of power and type: 220 or 110  10. Details of space available: Plenty of space  11. Do you require an automatic loading system: [**] Yes  [**] No  12. Do you require a gas scrubbing system: [**] Yes  [ ] No  13. How soon do you require the system to be delivered: 30  14. Any other specific requirements: 15. Nature: (Solid/Semi-solid/Liquid) Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system Imputing door Mouth Width (mm): 760*760 (approx.) Chimney External Diameter (mm): 300 ± 10 Combustion Improver Device: 0.11kw, Fuel consumption: 7kg/ hour (max) Re-Burning Device: Oil consumption: 5kg/h, 0.37kw, Oil consumption: 10-20kg/h Voltage: 380v/220v AC, Warranty: 1 Year, 50 Hz 

Medical waste incinerators bio Capacity incinerator medical waste to high combustion temperature

Medical waste incinerator bio Capacity incinerator medical waste to high combustion temperature  With a smokeless device to protect the environment and with two combustion chambers equipped with gas burners or oil  -incinerator to burn large volume pieces of 70 cm  deviation: Automatic Control System  -destructive capacity from 20 to 30 kgs  First-room / Temperature = 900 ° C combustion  2nd bedroom / Temperature = 1200 ° c afterburner  -burner = 116Kw Burning Rate: 50Kg/Hr Feed Capacity: 150Kgs  Primary Combustion Chamber: 900 Litres Secondary Combustion Chamber: 300 Litres Mix Combustion Chamber: Yes Smoke Filter Chamber: Yes Feed Mode: Manual Power: 0.7kW Fuel Type: Diesel/LPG/Natural Gas Internal Dimension: 120 x 90 x 85cm (Primary Chamber) External Dimensions: 200 x 160 x 310cm (Without Chimney) Burning Efficiency: >98%

Design standard Multiple chamber incinerator

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length  Width  Height  Extra width for burners At least 3000mm Loading door opening Minimum 700mm x 600mm Hearth area 5.00square meters Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated Primary chamber volume At least 3 cubic meters Mixing chamber volume At least 1 cubic meters Settling chamber volume At least 3 cubic meters Weight excluding chimney 15, 000kg at manufacture Firing tools supplied Hoe, Poker and rake

diesel Fuel incinerators

diesel Fuel incinerators 16.  The supplier must provide necessary information for the best of the installation.  This incinerator with “PYROLYTIC”  combustion must have: 17.  A combustion chamber of waste:   Perfectly tight door for the manual loading of waste.  The loading should be manual, batch load.   A burner of lighting which the use is limited to the ignition of waste.   Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out  of refractory.   The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and  insulates bricks in order to assure a minimum temperature on the outside sheet metal.   Composition of the refractory;   Refractory concrete:     Thickness :>100mm     Nature: 42% of Al203   Insulate in fibrous panels:     Thickness: >75mm   Nature: Calcium silicate.   Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of  electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.   Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 18.  A chamber of post combustion of gases   A burner of combustion of gases,   A device of injection of air allowing a total re-combustion of gases,   A device of air inlet of cooling of waste gases,   A sheath of evacuation of the gases burnt,   Carcass in strong sheet steel with support of connection   Composition of the refractory;   Refractory concrete:     Thickness :>150mm     Nature: 65%% of Al203   Insulate in fibrous panels:     Thickness: >85mm     Nature: Calcium   Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition,  permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.   A secondary injection of air to ensure perfect oxygen content.

Hot Medical Waste Disposing Machine Burn rate per hour: 250 -300kg/hr

Incinerator should be smokeless, odourless combustion and it should be made by high-quality cast, insulation, and steel plate as well as minimum generation of dust. Moreover the incinerator should be corrosion resistant.    Type Pyrolytic:- Hot Medical Waste Disposing Machine   Operation Condition 8-16 Hr /day Controls Built in data recording Incinerator /Primary Combustion Chamber Type: continuous loading Capacity/Burn rate per hour: 250 -300kg/hr Temperature:  900-1200 oC   Material: External- 3 layers Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, […]

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR Incinerator type: Animal waste incinerator Load Capacity minimum:  1500 kg Burner fuel type:  Diesel Burner fuel rate max.:   20-25 Liter diesel/ per hour Burners minimum: 3 Burning rate minimum: 200-300kg/per hour Furnace bar area minimum: 2 м3 Fuel tank capacity minimum: 300L Main chamber burning temperature min. 1100 0C Afterburner chamber burning temperature min.  1300 0C Power supply 220V Incinerator items and electrical appliances should be weather proof and humidity resistant within the range of 30-90 % Incinerator should be compliant to the environmental protection rules in accordance to national legislation Maximum dimensions C Length C 5m, width C 3.5m, height C 5m INCINERATOR, DIESEL, FIRED. Specifications Indicate if item offered complies with each specification.  1.1 General description   The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimum control of the operating conditions and incorporate a high capacity thermal oxidizing secondary chamber. It should be designed to retain the exhaust gases, for at least 2 seconds to ensure the unit’s effective destruction of the combustion products.   For the Supply, installation & commissioning of a Medical Waste Incinerator as detailed below: i. Waste type Health care waste   ii. Waste density 125 to 350Kg/M3   iii.. Waste Calorific Value 4000 KCAL/Kg   iv. Moisture content 10-25%   v.  Estimated ash  residue 5-10%   vi.  Nominal capacity  50Kg/hour batch load   vii.  Secondary chamber […]

Incinerator smokeless and odourless combustion-hot medical waste disposing machine

Incinerator should be smokeless, odourless combustion and it should be made by high-quality cast, insulation, and steel plate as well as minimum generation of dust. Moreover the incinerator should be corrosion resistant.  Type of incinerator : Pyrolitic – hot medical waste disposing machine Operation Condition: 8-16 hr/ day  Control: Built-in data recording Operating temperature: Incinerator  /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: continuous loading, Top Loading Capacity/Burn rate per hour: 250 -300 kg/hr  Material: External- 3 layers  Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock Secondary  Combustion  Chamber: Type: horizontal/vertical Temperature:  1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc  Auxiliary device: Fuel cut-off device Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                       Chimney (Stack): Type: Vertical type height:>7 meter’ Material: Fireproof cast, stainless steel OUTPUT:  GAS- SMOKELESS,ODORLESS  ASH -Max <5% of original waste size Reduction of Pollutant gas SO2, HCL, HF and line particulate Emission standard: WHO/ European Test report for emission testing provided? Heat exchange mode: Automatic Accessories:   All standard accessories for incinerator, including but not limited to loading system, heat exchangers, pollution control system, ash removal system, including ladder and oil tanker (2500litre capacity). Operating Environment:  The incinerator is capable to operate at the altitude of 2400mt above sea level. (according to the site conditions) Power Requirement: 220 Vac single phase or 380 Vac three phase 4 wire system  50HZ    Installation Testing and Commissioning :   to be conducted by certified or qualified personnel.   Supplier shall provide the following documentation     User (Operating) manual in English.  Service (Technical / Maintenance) manual in English.  Certificate of calibration and inspection from factory.  Fast moving spare parts: Supplier is able to provide fast moving spare parts with quantities as described in the price schedule or their equivalent.  Training: Supplier is able to provide training on operation, management and maintenance of incinerators.    Warranty  […]

Destroy the wasted materials or chemical uses in pharmaceuticals

Destroy the wasted materials or chemical uses in pharmaceuticals through Primary & Secondary combustion Chamber’s with working  temperatures are 850° C & 1100° C or 1200° C & 1400° C. The incinerator design must meet with ISO, OSHAS, Emission  Standards, Norms and Guidelines. The incinerator design must have heat recovery system and low fuel consumption system while  incineration.  The machine should have following features in its respective parts –  Feeding system Automatic/ and manual control system Automatic heating control system Easy maintenance  Outdoor type IP grade material Heat recovery system Low fuel consumption system  Combustion chamber dual type with heat recovery system Burner system with economizer / low fuel method Scrubbing system as per regulation Easy dust collecting system Chimney (height 50 meter) Record printing system Incinerators to be suitable for the professional disposal of clinical & medical waste / garbage with a higher load capacity in the range of approximately 1000-1500 Kg.  The durable, self-contained incinerators shall offer an effective and highly efficient, safe disposal and to be manufactured according to applicable international directives, e.g. CE, EU, etc. Type of Fuel: Diesel or Petrol or Natural Gas. Temperature controlled, efficient burner for optimum fuel economy. Units to be pre-assembled, pre-piped, pre-wired and tested before transport / export. Within the framework of an environmental and medical equipment & technology consultation and joint purchasing, this Procurement Bureau invites applicants for pre-qualification in the aim of primarily selecting capable companies to bid for the above tender.

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container,  supplied with the following specifications: complete with constant ventilation fans for extraction,  factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.  Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner  b. Dedicated independent fan system, damper controlled.  c. Thermostatic Sensor  d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor  c. Minimum Temperature of 1100 deg.C as per WHO guidelines.  d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate  b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play  c. Threezone monitoring of: i)Primary chamber               ii) Secondary chamber               iii) Hot hearth d. Digital display e. Burner on-off indication lights  f. Timer Chimney: a. Mild steel painted red b. Refractory insulated with 50mm of insulation. Unit Dimensions: 1840mm x 1 ‘1 50mm x 1950mm high. Safety: […]

200 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS

1) Policy – Waste disposal management shall be taken special note to prevent hospital infection. – Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site.   2) Waste Disposal Plan a) Classification – Medical wastes in hospital are classified as follows;   Infections Waste Specially-controlled waste […]