An operating test should be conducted to ensure that all of the control components have been properly installed and that all parts of the incinerator, including controls and safety devices, are in satisfactory operating condition. The requirements for prepurge and time between restarts should be verified. The test should include […]
medical incinerators in china
Would plant operations be operational on a basis of 24 hours per day, 7 days a week, all year long except for regular and preventive maintenance periods? How many hours per year could your process be operational? What would be your approach for larger projects aiming to valorize […]
INCINERATOR DIESEL DRIVEN
BURNER, DIESEL DRIVEN waste kind: MEDICAL CARE WASTE Waste calorific well worth: 4000KCAL/KG Dampness Content: 10-25%. Small Capacity: 50Kg/Hour set tons. 2nd Chamber: 2 Secs @ 850degrees C. The major burning chamber have to ensure very little leave temperature degree is not less than 850 levels C. INSULATION. Calcium Silicate. […]
medical waste heat value
18 Electrical supply required 3-phase 19 Auxiliary fuel Diesel or paraffin 20 Primary burner 21 Secondary (after) burner 22 Type of burners Automatic pressure jet 23 Output Primary Approx 600 000 kJ/hour 24 Output Secondary Approx 750 000kJ/hour 25 Emission control Heated refractory screen Low velocity grit arrester screen Built […]
hospital incinerator manufacturer
Up to 600kgs per ten-hour day of Type IV pathological waste or red bag waste rated at 2200 BTU’s per kg, based on batch loading twice daily. Incinerator, 20 kg/hr Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day) (4-6 hours operations) (Power Supply 380V, 50Hz, 3Ph) Capacity: 30 […]
medical small incinerator
Dimensions: World standard: 0.83m(I) x 1.0m(w) x 1.4m(h) Burning efficiency: >98% china double chamber incinerator Features: ? Waste type and burn rate: Designed specifically for use by poultry farmers, game-keepers and for pet cremation. The incinerator will burn up to 50 kg of waste per hour. ? Construction: Mild steel […]
medi burn 30 contraband incinerator
air retention for at least 2 seconds at a temperature of less than 850C, the combustion In order to achieve the proper effect. ? must be a two-chamber incinerators, primary and secondary Fuel stoves ? The waste products to reduce the initial volume Possible to minimize (approximately 5% sterile ash […]
red bag waste incinerator
“Waste chamber Chamber capacity 300 kg Chamber volume .54m3 Chamber size (outside) Width: 91cm, Height: 86cm Length: 152cm Door opening 66 x 76 cm Height to door 84 cm Height to top of stack 5.4 m Suggested slab size (L x W x Thickness) 1.8 m x 2.4 m x […]
incinerator 500kg per hr
The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C) Process Filtering system: Scruber to be mentionned as optional Emission Standards Compliance: BS 3316 or équivalent standard Version , the entire carcass of animals ( cattle , horses , Sheep, pigs , etc.) […]
incinerator for medical waste
Lifting Chains: Must be dual lifting chain of roller style & must meet safety factor at least 6:1. Hydraulic System: Durable cylinder with a chrome plated ram and a relief valve for overload protection Forks: Heavy duty steel approx. 4.0” wide x 42” long fixed forks Platform: solid steel Battery: […]
HEATER For incineration of Lab wastes products
Incinerators to be appropriate for the expert disposal of clinical & & & & medical waste/ rubbish with a better lots capability in the collection of about 1000-1500 Kg. The tough, self-contained burners will offer a exceptionally effective and effective, secure disposal in addition to be made according to appropriate […]
small incinerator for sale
Sterilization time: approx. 30 minutes at 121◦C/1.1 Bar or approx 15 minutes at 132◦C/2.5 Bar to achieve 6log10 sterility Fragmentation inside the chamber: Heavy duty with maximum size of final product <20 cm. Volume reduction of the waste after processing : by 60-80% through complete waste dehydration including liquid content […]
pet crematorium equipment
Finally, steam to the jacket should shut off, the unloading door is to be opened Then the shaft and mixing arms are reversed to act as unloading mechanism and should scoop the waste fragments out of the unloading door, onto a conveyor belt or directly into a waste container. The […]
hospital incinerator manufacturers
SECTION V TECHNICAL SPECIFICATIONS OF THE INCINERATOR General Description The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to: Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers […]
medical incinerator design
It is expected that the Bidder will cooperate closely with PATH and target Hospitals for the new waste handling building/area and will make available all needed technical information, drawings, etc., The following waste streams shall be treated in the new HCW treatment center(s): Infectious waste Sharps waste […]
animal cremation equipment prices
The following requirements are to be considered as an integral part of the technical specifications for each equipment type. The system offered shall be designed to operate normally under the conditions of different regions in Kenya. These conditions may include but not limited to power supply, temperature, […]
medical incinerator primary combustion price
Equipped with main combustion chamber and a second chamber for reburning designed to ensure complete combustion of the gases resulting from incomplete combustion of inert gases in the chimney, within the standards recommended by the World Health Organization; Equipped with temperature controller to adjust the air of the combustion […]
incinerators for sale from china
Incinerators used will be limited to daylight hours of operation. This includes shutdown, cleaning and maintenance. Waste streams shall not be mixed during the incineration process and the ash collection chamber will be cleaned when a different waste stream is to be incinerated. The Company will provide the contractor […]
waste incinerator manufacturers china
5-1- Chambre de post combustion est installée au dessus du foyer de combustion , elle est constituée d’un cylindre métallique revêtu intérieurement d’une couche d’ isolant et d’une couche de matériaux réfractaires. 5-2- Volume intérieur?: 2,1 m3 Est dimensionnée pour pouvoir garantir un temps de fumée de 2 secondes à […]
CLINICAL BIOLOGICAL WASTE BURNER
It must be a 3 chambered burner The loads ability of 250 kg The realty for the incinerator requirement to be able to stand up to the temperatures and additionally different other useful demands. The smokeshaft should certainly have a solid refractory cellular lining of special type of concrete to […]
small capacity incinerators
Capacité destructive de 55 Kg/h jour de déchets hospitaliers avec un p?.c. i jusqu’à 3.200 Kcal/Kg 1)Type de déchet hospitalier 2)Pouvoir calorifique inférieur 3.200 kcal/kg 3)Humidité 20% 4)Teneur en cendres et/ou inertes 8% 5)Capacité destructive nominale 55 kg/h 6)Volume chambre de combustion 1,65 m3 7)Volume chambre postcombustion 2.1 m3 8)Temps […]
Required Specifications for Mobile Incinerator
Operational Capabilities PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS ABILITY TO BURN WASTE LUBRICANTS (POL) HANDLE ORGANIC SOLIDS (TO INCLUDE RMW) DEPLOYABLE MOBILE 24 HRS OF CONTINUOUS USE AUTOMATIC LOADING […]
china medical waste incinerator
Incinerate: medical waste and general waste Capacity to burn waste: 400 — 500 kg/hr Fuel: Diesel Fuel Consumption: 10 litres/hr maximum Incineration temperature: 950 – 1300 °c Casing: thick (min 5 mm) Stainless steel casing and fully insulated to withstand sea humidity Voltage: 220/240 V or 380/415V Frequency: 50 Hz […]
20kgs per hour incinerator
The manufacturer must provide a declaration that the pressure vessel is manufactured in accordance with relevant guidelines for pressure equipment. Following accompanying documents should be supplied with the treatment system and shall be available at the Site: 1.Operation instructions (including process description). 2.Loading and maintenance procedures. 3.Short-form of […]
incinerators 300 kg per hour
Manual autoclave with vertical loading; gravity displacement type with possibility for Vacuum. Capacity: Up to 12 kg/h Chamber size: >150 liters Material: Stainless steel Temperature: 134 °C Further information: Minimum autoclave chamber size shall be 150 liters and shall have a usable volume (loading […]
incinerators 150 kg per hour
combustion chamber and one flue gas afterburning chamber. The incinerator must be able to meet the following parameters: 1.Treatment capacity of: a) 50 kg waste per hour. 2.Temperature: Main combustion chamber up to 850°C, and in the second chamber > = 1,100 °C 3.Retention Time: 2 seconds […]
pet crematory equipment
Physical /Chemical Characteristics: Boiling Point (_F) : N/A Appearance & Odor: Off white, odorless Vapor Pressure(mm Hg): N/A Volatiles (% by weight): N/A Vapor Density (Air =1) :N/A Evaporation Rate )n-butylacetate=1): N/A HMIS Classification : Health:1; Flammability: 1 Reactivity Data: Stability: Stable Conditions to Avoid: None Know Incompatibility […]
incinerator suppliers
1.Solidifier (Fluid waste disposal product) Liquid Waste Solidifier for Water Based Special Features of Solidifier 2lb bottle Effectively solidifies potentially serious infectious waste quickly Quickly8 penetrates to solidify blood and body fluid to convert Gels in seconds No shaking required Retrains solidity to prevent spills and leaks for safe […]
About Hiclover Medical Enviromental
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction […]
medical incinerator 20kg
We are looking for small incinerators with filter (with least minimum pollution) for burning/combusting 5kg/hr, 10kg/hr, 15 kg/hr, 20kg/hr, 25kg/hr to 50kg/hr and 300kg/hr of SOLID ORGANIC DRY AND WET NON-HAZARDUOUS of any kind (including hospital wastes) per day or per hour. Should it be with no smoke, no fumes, […]
incineration in china
Combustion Efficiency 99.99% Retention time Of the flow gases not less than 2 Sec in the hot portion. Excess Oxygen concentration Of primary combustion chamber 3-6% max. Refractory The chambers should be lined with high thermal insulating refractory bricks with suitable thickness and with highly temp. resistance. Not less than […]
medical waste incinerators china
Ensure flame contact with all gases is achieved. –yes Ensure residence time is not less than two (2) seconds. –yes Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is not less than 1100oC.—1000-1200 oC Ensure the oxygen […]
incinerators animal
Class 2 Industrial Incinerators Class 2A: Commercial Incinerators for the disposal of waste that contains hazardous, potential hazardous and bio-medical waste where the operator exceeds 100 Kg/day. Dimensions: 2.2m(l) x 1.5m(w) x 2.5m(h) Fully automatic computer multi control system. Fuel Options- Diesel and natural gas, electricity Wasted fuel- >12L/h […]
manufacturer of ha zardous waste incinerator in china
?Incinerate minimum 80kg/hr X 12 hrs per day ?Disposal of both non-hazardous and hazardous waste streams (per waste inventory) ?Mobile Unit (Skid mounted preference with lifting points) Design/Specifications ?Incinerators must have a secondary combustion chamber with a minimum temperature range of 900c ?Liquid waste streams shall be incinerated by an […]
mobile incinerator design
The Authority may require that the certificate holder have tests carried out by an accredited institution to determine stack and/or ground level concentrations of the following substances. Cadmium and compounds as Cd Mercury Hg Thallium Tl Chromium Cr Beryllium Be Arsenic As Antimony Sb Barium Ba Lead Pb […]
BURNER DIESEL FIRED
Heater 20 Kg Burner electrically ran containing: A cage for receipt of biomedical waste; A burning chamber with fireplace with a filter to preserve ashes; A cover; An air supply; A wind generator allowing supply air. Burning temperature: 1800 ° C. Consists of all gadgets. ▪ The burner ought to […]
pet cremation incinerator cost
Intermittent Feed (w/optional loader): .9 yd3/hr (.7 m3/hr) up to 8 hrs/day Specifications: Length overall -9′-6″ (2896 mm) batch system w/o loader 18′-6″ (5639mm) w/optional loader system Width overall -7′-6″ (2820mm) Height (w/o stack) -10′-0″ (3048mm) Approx. Weight […]
china lab waste incinerators
.Necessary tooling and gauges shall have also to be supplied. 14.Supplier shall have to arrange free training for user staff in operation and maintenance 15.Supplier shall have to provide related drawings/diagrams (civil, mechanical and electrical etc.)electrical load and electrical circuitry 16.Warranty period shall be 24 months from […]
Contact Us
Nanjing Clover Medical Technology Co., Ltd. Tel: +86-25-8461 0201 Fax: +86-25-8461 0406 Website: www.inciner8.cn Email: [email protected] Service Skype: clover-incinerator Pусский: www.hiclover.ru 中文: www.haiwo.net Photo Gallery: www.eclover.net Clover News: www.incinerator.info Facebook: www.facebook.com/hiclover Twitter: twitter.com/hiclovercom YouTube: youtube.com/c/IncineratorClover Send Message by below contact form: Contact Form
FAQs
Q: what is kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. Q: Incinerator Smoke Standard A: China Government Standard: No.GB18484-2001. Q: Treatment capacity A: Average […]
Project Case
Waste Incinerator International Market Analytics Date. Jun. 10, 2012 Key Word: small incinerators medical waste incinerator pet animal cremation incinerator incinerator manufacturers Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below: […]
About Us
Nanjing Clover Medical Technology Co.,Ltd. local in Nanjing city, China which is near to Shanghai port. We are Waste Incinerator Manufacturer in China. We produce medical waste incinerators, pet animal cremation equipment and othe solid waste incinerators. The burning rate from 10kgs,20kgs,30kgs,50kgs,100kgs,150kgs,200kgs,300kgs,500kgs,600kgs per hour, the daily treatment capacity up to […]
hospital incinerator distributor
CSH Wellness Facility, (Calabar, Nigeria) Mmedical waste burner qualified of obtaining rid of roughly 0.5 cubic meter of pathological or contagious waste. Burner to have twin burning chamber as well as control amount of dioxin as well as various other gasses discharged without being damaging. Approximated measurements, to distributors common, […]
burner suppliers
incinerator providers.7) Burn cost: 15 – – – – 20 Kg/h 8) Ability: very little less than 130 L. 9) Concentrations of numerous contaminants in heap gases listed below discovery limitations. 10) Gasoline. 11) Electronic system control. 12) Easy to run and also really little training. 13) Any kind of […]
heater for medical waste
heater for medical waste.Controlled air clinical waste incinerator produced for incineration of bio-medical waste created at a blood-processing center. The waste to be handled mainly includes bio-waste (i.e. physical fluids), transmittable and likewise polluted products such as syringes, needles, as well as other clinical waste (i.e. silicon rubbers, plastic, fabrics, […]
INCINERATEUR BURNING DAMAGES OF MEDICAL WASTE PYROLYTIC Along With LABORATORY
Usage diesel, construction in repainted steel resistant aluminium at heats up, fire device control indication, billing indicator, temperature level control gadget, melting ability of 250 kg/ hr in 2 phases (2nd and primary electronic camera). INCINERATEUR BURNING DEVASTATION OF MEDICAL WASTE PYROLYTIC AND ALSO LABORATORY. 1. CAPABILITY OF GARBAGE DISPOSAL: […]
Medical waste incineration system
Medical waste incineration system of 300 kg/hr lost price with double gas (gas along with diesel) type, everyday 8-16 hrs treatment and also a stack altitude of 15 meter.Primary burning i. The primary combustion chamber will be accepted as the crucial burning area; ii. The marginal burning temperature of the […]
arrangement of waste non multiple-use burner system
installment of waste non reusable system in airport.Incinerator with oil heater Capability 2 ton/day, Oil storage tank 300 l Oil pump 0.4 Kw, Heating unit 0.2 Kw. Variation: YD Collection. – Diesel heater. It will definitely have usually paper, cardboard and likewise food, though also it will absolutely blaze medical […]
a DUCK ranch heater
a DUCK farm burner, we require to acquire a tool size incinerator for organic waste, a lot more specific DUCKS.an animal dog crematorium in ireland.Equipment Double chamber medical infectious waste burner Capacity 10-30 kg per hr Features of waste The list listed below average features are thought about *: residence […]
Dual-chamber controlled air heater or dual- chamber pyrolytic heater
Types of burner style appropriate: Dual-chamber regulated air heater or double- chamber pyrolytic incinerator Products of building: The incinerator shall not have any type of type of asbestos, asbestos-containing compounds, mercury thermostats, as well as additionally mercury switches. Refractory products shall have the capability to satisfy pertinent standards under ISO […]
GENERAL SPECS FOR HEATERS
Main as well as extra burners: Different electrically spark-ignited major heating units along with second heating systems with automatic control will certainly be used to accomplish the specified temperature level needs in the additionally added as well as major chambers. The fires of the main and also additional heating units […]