Skip to content
Menu
Waste Incinerator Newsletter
  • Home
  • About
  • Products
  • Blog
Waste Incinerator Newsletter

Water cooled furnaces, primary and secondary furnaces, and forced air supply type for incineration of medical waste

Posted on October 28, 2020November 5, 2021 by HICLOVER.COM

The Product shall be used for incineration of medical waste and general waste generated at hospitals in the Democratic Republic of the Congo.
The Product shall combust the wastes completely in order to reduce environmental load by exhaust gas and avoid the generation of dioxin.
The insignia of National Flag of Japan shall be painted onto both sides of the Product.
Language used for indications on panel and other instructions shall be French.
“Approx.”, if any, means a numerical value ±10% of the described figures.
Main unit 1 set/unit
Main unit
1) Type Water cooled furnaces, primary and secondary furnaces, and forced air supply type
2) Burning capacity 320 kg/8h or more
3) Hearth size 1.0 m2 or more
4) Furnace capacity 1.1 m3 or more
5) Material of major part
a Main frame SS400 of rolled steels for general structure or equivalent
b Fire bed Cement castable or equivalent
6) Painting Aluminium paint, to comply with JIS K 5492
7) Primary combustion chamber
a Combustion temperature 800 degC or more
b Water jacket
(a) Capacity 1500 L or more
(b) Water feed tank Equipped
c Temperature sensor Equipped
d Waste inlet dimension Approx. W 550 × H 500 mm
e Ash outlet dimension Approx. W 400 × H 350 mm
8) Secondary combustion chamber
a Combustion temperature 1050 degC or more
b Steam exhaust pipe Equipped
9) Exhaust system
a Exhaust pipe Approx. dia. 380 × L 4500 mm
b Ejector pipe
(a) Size Approx. dia. 139.8 mm
(b) Material SGP or equivalent
(c) Air damper Equipped
c Dust collector
(a) Type Cyclone dust collector
(b) Dust box Equipped
10) Neutralizing reaction device
a Type Effluent gas processing system or equivalent
b Processing method Spraying solution or equivalent
c Spray nozzle
(a) Consumption rate 3.8 L/h or more
(b) Material Stainless steel
(c) Number of nozzle 2 sets/unit or more
(d) Air cooling device for Equipped
nozzle
d Solution tank
(a) Capacity 30 L or more
(b) Material PE or equivalent
(c) Control valve Equipped
e Pump for spray nozzle
(a) Type Electro-magnetic pump
(b) Flow rate 18 L/h or more
(c) Max. pressure 1 MPa or more
(d) Output 0.033 kW or more
f Control switch box Equipped
g Chloride trap screen
(a) Material Stainless steel
(b) Number of screen 4 or more
11) Blower
a Type High pressure turbo fun or equivalent
b Output 3.7 kW or more
c Max. flow rate 45 m3/min or more
d Max. pressure 4.5 kPa or more
12) Burner
a Type Ignite burner and afterburner, each 1 set/unit
b Fuel Kerosene or diesel
13) Fuel tank 198 L or more
14) Control box and panel Equipped,
outdoor type,
including control timer and warning buzzer
15) Gas sampling hole Equipped
16) Peeping hole Equipped, if any
17) Weight 1600 kg or less
18) Weight in operation 3200 kg or less
19) Dimensions of main unit, excluding external unit and accessories Approx. W 3000 × D 2050 ×H 8340 mm
20) Power supply AC 380 V, 50 Hz, 3-phase, to be directly connected to the distribution board prepared by the End-User
Attachments and Accessories
1) Goggles 3 pairs/unit
2) Cotton work gloves 12 pairs/unit
3) Iron bar for treating ash 1 pc/unit
4) Iron bar for scrambling ash 1 pc/unit
5) Manufacturer’s standard accessories 1 set/unit, to be specified by Tenderer
Spare parts 1 set/unit, including spare parts for burner, to be specified by Tenderer
The name and model number of each spare parts shall be described in SCHEDULE-IV SPARE PARTS LIST, PART VII FORMS OF TENDER.

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Email: sales@hiclover.com
Email: hicloversales@gmail.com
  
Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2020-10-28

Related posts:

  1. Newsletter – medical waste
  2. Newsletter – incinerator
  3. Newsletter – incinerator
  4. Newsletter – medical waste
  5. Newsletter – waste incinerator
  6. Newsletter – incinerator
  7. Newsletter – medical waste
  8. Newsletter – medical waste

Recent Posts

  • Newsletter – medical waste
  • Newsletter – enviromental
  • Newsletter – incinerator
  • Newsletter – medical waste
  • Newsletter – incinerator

Recent Comments

  1. The Mufflerman on U.S. EPA fines California auto parts companies for selling ‘defeat’ devices, harming air quality
  2. Laura Bush on U.S. EPA fines California auto parts companies for selling ‘defeat’ devices, harming air quality
  3. aaronssd on EPA Announces $160,000 Grant to Nevada’s greenUP! for Green Manufacturing, Pollution Prevention
  4. glassline on EPA Announces $160,000 Grant to Nevada’s greenUP! for Green Manufacturing, Pollution Prevention
  5. Community Health and Wellness Center on Medical Surgical Face Mask Machine for Coronavirus Disease COVID-19
©2025 Waste Incinerator Newsletter | Theme: Wordly by SuperbThemes