Posted on February 24, 2021November 5, 2021 by HICLOVER.COM

Items/Model

TS300(PLC)

Picture

 

Principle

Solid Waste Incineration Treatment

Burn Rate

Average 300 kg/hour

Feed Capacity

Average 400kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

2000L

Internal Dimensions

170x120x100cm

Secondary Chamber

1000L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

2.0Kw

Oil Consumption (kg/hour)

Average 38(DO)

Gas Consumption (m3/hour)

Average 45.6(NG)

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

11000kg

External Dimensions

400x210x300cm(without chimney)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Email: sales@hiclover.com
Email: hicloversales@gmail.com
  
Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


Controlled hygienic, mechanical or automatic feeding methods must not negatively influence the air supply and temperature in the primary and secondary chambers of the incinerator.
“Each unit shall include a diesel fuel storage tank of sufficient capacity to enable operation of the unit for 5 working days of 10 hours each.
• The unit shall include a pumping system and lines to supply the burners from the tank and the diesel-electric generator.  The pumping system will have two pumps in parallel for redundancy.
• The supply lines will be fabricated from steel tubing and adequately protected and supported against damage during operations and include shutoff valves for each line. 
• The unit shall be equipped with a fuel meter.
“
“The waste incinerators shall be designed for the following electricity supply:
• 3 phase, 4 wire, 415 V a.c. ±10%, 50 Hz ±3%  
• 3 phase 4 wire, 220 V a.c. ±10%, 60 Hz ±3%
Incinerators must  be able to support different power sources (PV solar system , diesel Electric generator , local or  compound mini-scale grid)

 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-24

Related posts:

  1. Newsletter – medical waste
  2. Newsletter – enviromental
  3. Newsletter – incinerator
  4. Newsletter – medical waste
  5. Newsletter – medical waste
  6. Newsletter – medical waste
  7. Newsletter – incinerator
  8. Newsletter – medical waste

Recent Posts

  • Newsletter – medical waste
  • Newsletter – enviromental
  • Newsletter – incinerator
  • Newsletter – medical waste
  • Newsletter – incinerator

Recent Comments

  1. The Mufflerman on U.S. EPA fines California auto parts companies for selling ‘defeat’ devices, harming air quality
  2. Laura Bush on U.S. EPA fines California auto parts companies for selling ‘defeat’ devices, harming air quality
  3. aaronssd on EPA Announces $160,000 Grant to Nevada’s greenUP! for Green Manufacturing, Pollution Prevention
  4. glassline on EPA Announces $160,000 Grant to Nevada’s greenUP! for Green Manufacturing, Pollution Prevention
  5. Community Health and Wellness Center on Medical Surgical Face Mask Machine for Coronavirus Disease COVID-19
©2025 Waste Incinerator Newsletter | Theme: Wordly by SuperbThemes