Large Size Burning Rate:150-200 kg/hr Solid Waste Equipment Primary and Secondary Combustion Chamber Incinerator

Posted on March 21, 2020November 6, 2021 by HICLOVER.COM

Items/Model

TS500(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

150-200 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

2700L

Internal Dimensions

190x120x120cm

Secondary Chamber

1300L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Oil Consumption (kg/hour)

Average 28

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

15000kg

External Dimensions

400x210x300cm(without chimney)

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;

HICLOVER – Medical Environmental 


 

WWW.HICLOVER.COM
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Related posts:

  1. Newsletter – incinerator
  2. Newsletter – medical waste
  3. Newsletter – medical waste
  4. Newsletter – medical waste
  5. Newsletter – medical waste
  6. Newsletter – medical waste
  7. Newsletter – medical waste
  8. Newsletter – medical waste

Recent Posts

  • Newsletter – medical waste
  • Newsletter – enviromental
  • Newsletter – incinerator
  • Newsletter – medical waste
  • Newsletter – incinerator

Recent Comments

  1. The Mufflerman on U.S. EPA fines California auto parts companies for selling ‘defeat’ devices, harming air quality
  2. Laura Bush on U.S. EPA fines California auto parts companies for selling ‘defeat’ devices, harming air quality
  3. aaronssd on EPA Announces $160,000 Grant to Nevada’s greenUP! for Green Manufacturing, Pollution Prevention
  4. glassline on EPA Announces $160,000 Grant to Nevada’s greenUP! for Green Manufacturing, Pollution Prevention
  5. Community Health and Wellness Center on Medical Surgical Face Mask Machine for Coronavirus Disease COVID-19
©2025 Waste Incinerator Newsletter | Theme: Wordly by SuperbThemes