HICLOVER – Medical Environmental
Model |
YD-30 (Custom Edition) |
Picture |
|
Burning Rate |
average 30 kgs/hour |
Feed Capacity |
average 40 kgs |
Paimary Combustion Chamber |
200 Liters |
Secondary Combustion Chamber |
100 Liters |
Mix Combustion Chamber |
Yes |
Feed Mode |
Manual |
Voltage |
220V |
Power |
0.59Kw |
Fuel Type |
Diesel Oil |
Burner |
Italy Original |
Oil Consumption (Diesel Oil) |
average 13.3 kg/hour |
Gas Consumption (Natural Gas) |
*** |
Internal Dimensions |
80 x 50 x 50cm (primary chamber) |
External Dimensions |
125 x 90 x 180cm (without chimney) |
Temperature Monitor |
Yes |
Oil Tank Capacity(if oil fuel) |
60 Liters |
Door Opening |
40 x 40cm |
Chimney Length |
1.0 Meters |
Chimney Type |
Stainless Steel |
Equipment Gross Weight |
1500 kgs |
Operation Technical Specifications |
Paimary Chamber Temperature |
800℃–1000℃ |
Secondary Chamber Temperature |
1000℃-1200℃ |
Residency Time |
2.0 Sec. |
Burning Efficiency |
>98% |
Waste Lower Calorific Power |
3000Kcal |